{"id":32827,"date":"2024-06-05T08:50:52","date_gmt":"2024-06-05T08:50:52","guid":{"rendered":"https:\/\/coral-i.co.za\/test-equipment\/?post_type=product&#038;p=32827"},"modified":"2024-06-05T08:50:52","modified_gmt":"2024-06-05T08:50:52","slug":"ceyear-6433d-f-h-l-lightwave-component-analyzer-10mhz-20ghz-43-5ghz-50ghz-67ghz","status":"publish","type":"product","link":"https:\/\/coral-i.co.za\/test-equipment\/product\/ceyear-6433d-f-h-l-lightwave-component-analyzer-10mhz-20ghz-43-5ghz-50ghz-67ghz\/","title":{"rendered":"Ceyear 6433D\/F\/H\/L Lightwave Component Analyzer (10MHz &#8211; 20GHz\/43.5GHz\/50GHz\/67GHz)"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"https:\/\/image.made-in-china.com\/202f0j00zeHhiUacqurC\/6433D-Lightwave-Component-Analyzer-10MHz-20GHz-.jpg\" alt=\"6433D Lightwave Component Analyzer (10MHz - 20GHz) - China Lightwave Component Analyzer, Component Analyzer | Made-in-China.com\" width=\"488\" height=\"405\" \/><\/p>\n<p><strong>Main Features:<\/strong><\/p>\n<ul>\n<li>Easy &amp; quick calibration, and guided operation\u00a0process<\/li>\n<li>Integrated multi-functional operation\u00a0interface<\/li>\n<li>Large dynamic range, low noise of measurement\u00a0path<\/li>\n<li>Automatic user data removal that provides extended use for on-chip\u00a0testing<\/li>\n<li>Single -ended &#8211; balanced photoelectric device\u00a0measurement<\/li>\n<li>Multi-functional\u00a0toolbox<\/li>\n<li>Internal &amp; external wavelength setting of light sources, and wider test range of communication\u00a0wavelength<\/li>\n<\/ul>\n<p><strong>Technical Specifications:<\/strong><\/p>\n<div>\n<h2><b>6433D Technical Specifications (10MHz &#8211; 20GHz)<\/b><\/h2>\n<div class=\"rich-text-table\">\n<table width=\"1326\">\n<tbody>\n<tr>\n<td>Modulation Frequency Range<\/td>\n<td>10MH z\u00a0~\u00a020 GHz<\/td>\n<\/tr>\n<tr>\n<td>Frequency Accuracy<\/td>\n<td>\u00b11\u00d710\u00a0-7<\/td>\n<\/tr>\n<tr>\n<td>Frequency Resolution<\/td>\n<td>1 Hz<\/td>\n<\/tr>\n<tr>\n<td>Working Wavelength<\/td>\n<td>1310\u00b120nm, 1550\u00b120nm<\/td>\n<\/tr>\n<tr>\n<td>Average Output Optical Power Range<\/td>\n<td>-2 dBm~+4 dBm<\/td>\n<\/tr>\n<tr>\n<td>Maximum Safe Average Input Power<\/td>\n<td>Input 1: +7dBm \/ Input 2: +17dBm<\/td>\n<\/tr>\n<tr>\n<td>Average Output Optical Power Accuracy<\/td>\n<td>\u00b10.5 dB<\/td>\n<\/tr>\n<tr>\n<td>Average Input Optical Power Measurement Range<\/td>\n<td>-35dBm~+5dBm (optical input 1) \/ -25dBm~+15dBm (optical input 2)<\/td>\n<\/tr>\n<tr>\n<td>Average Input Optical Power Measurement Accuracy<\/td>\n<td>\u00b10.5 dB<\/td>\n<\/tr>\n<tr>\n<td>Relative Frequency Response Accuracy<\/td>\n<td>\u00b1 0.7 dB<\/td>\n<\/tr>\n<tr>\n<td>Absolute Frequency Response Accuracy<\/td>\n<td>\u00b1 1.8 dB<\/td>\n<\/tr>\n<tr>\n<td>Frequency Response Repeatability<\/td>\n<td>\u00b1 0.3 dB<\/td>\n<\/tr>\n<tr>\n<td>Group Delay Measurement Accuracy<\/td>\n<td>\u00b1 13 ps<\/td>\n<\/tr>\n<tr>\n<td>Phase Measurement Accuracy<\/td>\n<td>\u00b1 3.5 \u00ba<\/td>\n<\/tr>\n<tr>\n<td>Maximum Weight<\/td>\n<td>56 kg<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>Width high depth = 421mm \u00d7 400mm \u00d7 600mm (excluding feet, hands)<\/td>\n<\/tr>\n<tr>\n<td>Maximum Power Consumption<\/td>\n<td>600 W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<div>\n<p><b>6433F Technical Specifications (10MHz &#8211; 43.5GHz)<\/b><\/p>\n<div class=\"rich-text-table\">\n<table width=\"1330\">\n<tbody>\n<tr>\n<td>Modulation Frequency Range<\/td>\n<td>10MH z\u00a0~\u00a043.5 GHz<\/td>\n<\/tr>\n<tr>\n<td>Frequency Accuracy<\/td>\n<td>\u00b11\u00d710 -7<\/td>\n<\/tr>\n<tr>\n<td>Frequency Resolution<\/td>\n<td>1 Hz<\/td>\n<\/tr>\n<tr>\n<td>Working Wavelength<\/td>\n<td>1310\u00b120nm, 1550\u00b120nm<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Average Output Optical Power Range<\/td>\n<td>-2dBm~+4dBm (1310nm)<\/td>\n<\/tr>\n<tr>\n<td>-2dBm~+5dBm (1550nm)<\/td>\n<\/tr>\n<tr>\n<td>Maximum Safe Average Input Power<\/td>\n<td>Input 1: +7dBm \/ Input 2: +17dBm<\/td>\n<\/tr>\n<tr>\n<td>Average Output Optical Power Accuracy<\/td>\n<td>\u00b10.5 dB<\/td>\n<\/tr>\n<tr>\n<td>Average Input Optical Power Measurement Range<\/td>\n<td>-35dBm~+5dBm (optical input 1) \/ -25dBm~+15dBm (optical input 2)<\/td>\n<\/tr>\n<tr>\n<td>Average Input Optical Power Measurement Accuracy<\/td>\n<td>\u00b10.5 dB<\/td>\n<\/tr>\n<tr>\n<td>Relative Frequency Response Accuracy<\/td>\n<td>\u00b1 1.6 dB<\/td>\n<\/tr>\n<tr>\n<td>Absolute Frequency Response Accuracy<\/td>\n<td>\u00b1 2.0 dB<\/td>\n<\/tr>\n<tr>\n<td>Frequency Response Repeatability<\/td>\n<td>\u00b1 1.0 dB<\/td>\n<\/tr>\n<tr>\n<td>Group Delay Measurement Accuracy<\/td>\n<td>\u00b1 18 ps<\/td>\n<\/tr>\n<tr>\n<td>Phase Measurement Accuracy<\/td>\n<td>\u00b1 4.2 \u00ba<\/td>\n<\/tr>\n<tr>\n<td>Maximum Weight<\/td>\n<td>60 kg<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>Width high depth = 421mm \u00d7 400mm \u00d7 600mm (excluding feet, hands)<\/td>\n<\/tr>\n<tr>\n<td>Maximum Power Consumption<\/td>\n<td>600 W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><b>6433H Technical Specifications (10MHz &#8211; 50GHz)<\/b><\/p>\n<div class=\"rich-text-table\">\n<table width=\"1328\">\n<tbody>\n<tr>\n<td>Modulation Frequency Range<\/td>\n<td>10MH z\u00a0~\u00a050 GHz<\/td>\n<\/tr>\n<tr>\n<td>Frequency Accuracy<\/td>\n<td>\u00b11\u00d710 -7<\/td>\n<\/tr>\n<tr>\n<td>Frequency Resolution<\/td>\n<td>1 Hz<\/td>\n<\/tr>\n<tr>\n<td>Working Wavelength<\/td>\n<td>1310\u00b120nm, 1550\u00b120nm<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Average Output Optical Power range<\/td>\n<td>-2dBm~+4dBm (1310nm)<\/td>\n<\/tr>\n<tr>\n<td>-2dBm~+5dBm (1550nm)<\/td>\n<\/tr>\n<tr>\n<td>Maximum Safe Average Input Power<\/td>\n<td>Input 1: +7dBm \/ Input 2: +17dBm<\/td>\n<\/tr>\n<tr>\n<td>Average Output Optical Power Accuracy<\/td>\n<td>\u00b10.5dB<\/td>\n<\/tr>\n<tr>\n<td>Average Input Optical Power Measurement Range<\/td>\n<td>-35dBm~+5dBm (optical input 1) \/ -25dBm~+15dBm (optical input 2)<\/td>\n<\/tr>\n<tr>\n<td>Minimum Measurable Frequency Response<\/td>\n<td>-60 dB<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<div>\n<div class=\"rich-text-table\">\n<table width=\"1329\">\n<tbody>\n<tr>\n<td>Average Input Optical Power Measurement Accuracy<\/td>\n<td>\u00b1 0.5 dB<\/td>\n<\/tr>\n<tr>\n<td>Relative Frequency Response Accuracy<\/td>\n<td>\u00b1 1.6 dB<\/td>\n<\/tr>\n<tr>\n<td>Absolute Frequency Response Accuracy<\/td>\n<td>\u00b1 2.5 dB<\/td>\n<\/tr>\n<tr>\n<td>Frequency Response Repeatability<\/td>\n<td>\u00b1 1.7 dB<\/td>\n<\/tr>\n<tr>\n<td>Group Delay Measurement Accuracy<\/td>\n<td>\u00b1 18 ps<\/td>\n<\/tr>\n<tr>\n<td>Phase Measurement Accuracy<\/td>\n<td>\u00b1 4.2 \u00ba<\/td>\n<\/tr>\n<tr>\n<td>Maximum Weight<\/td>\n<td>60 kg<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>Width high depth = 421mm \u00d7 400mm \u00d7 600mm (excluding feet, hands)<\/td>\n<\/tr>\n<tr>\n<td>Maximum Power Consumption<\/td>\n<td>600 W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><b>6433L Technical Specifications (10MHz &#8211; 67GHz)<\/b><\/p>\n<div class=\"rich-text-table\">\n<table width=\"1332\">\n<tbody>\n<tr>\n<td>Modulation Frequency Range<\/td>\n<td>10MH z\u00a0~67 GHz<\/td>\n<\/tr>\n<tr>\n<td>Frequency Accuracy<\/td>\n<td>\u00b11\u00d710 -7<\/td>\n<\/tr>\n<tr>\n<td>Frequency Resolution<\/td>\n<td>1 Hz<\/td>\n<\/tr>\n<tr>\n<td>Working Wavelength<\/td>\n<td>1310\u00b120nm, 1550\u00b120nm<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Average Output Optical Power Range<\/td>\n<td>-2dBm~+4dBm (1310nm)<\/td>\n<\/tr>\n<tr>\n<td>-2dBm~+5dBm (1550nm)<\/td>\n<\/tr>\n<tr>\n<td>Maximum Safe Average Input Power<\/td>\n<td>Input 1: +7dBm \/ Input 2: +17dBm<\/td>\n<\/tr>\n<tr>\n<td>Average Output Optical Power Accuracy<\/td>\n<td>\u00b10.5 dB<\/td>\n<\/tr>\n<tr>\n<td>Average Input Optical Power Measurement Range<\/td>\n<td>-35dBm~+5dBm (optical input 1) \/ -25dBm~+15dBm (optical input 2)<\/td>\n<\/tr>\n<tr>\n<td>Minimum Measurable Frequency Response<\/td>\n<td>-55 dB<\/td>\n<\/tr>\n<tr>\n<td>Average Input Optical Power Measurement Accuracy<\/td>\n<td>\u00b1 0.5 dB<\/td>\n<\/tr>\n<tr>\n<td>Relative Frequency Response Accuracy<\/td>\n<td>\u00b1 2.2 dB<\/td>\n<\/tr>\n<tr>\n<td>Absolute Frequency Response Accuracy<\/td>\n<td>\u00b1 2.7 dB<\/td>\n<\/tr>\n<tr>\n<td>Frequency Response Repeatability<\/td>\n<td>\u00b1 1.7dB<\/td>\n<\/tr>\n<tr>\n<td>Group delay Measurement Accuracy<\/td>\n<td>\u00b1 31 ps<\/td>\n<\/tr>\n<tr>\n<td>Phase Measurement Accuracy<\/td>\n<td>\u00b1 6.0 \u00ba<\/td>\n<\/tr>\n<tr>\n<td>Maximum Weight<\/td>\n<td>63 kg<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>Width high depth = 421mm \u00d7 400mm \u00d7 600mm (excluding feet, hands)<\/td>\n<\/tr>\n<tr>\n<td>Maximum Power Consumption<\/td>\n<td>600 W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p><b>Order Information<\/b><\/p>\n<div class=\"rich-text-table\">\n<table width=\"1317\">\n<tbody>\n<tr>\n<td><b>No.<\/b><\/td>\n<td><b>Model and Name<\/b><\/td>\n<td><b>Description<\/b><\/td>\n<\/tr>\n<tr>\n<td>1<\/td>\n<td>6433D Lightwave Component Analyzer (dual port)<\/td>\n<td>Electric channel is 2 ports<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>6433D Lightwave Component Analyzer (four ports)<\/td>\n<td>Electric channel is 4 ports<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>6433F Lightwave Component Analyzer (dual port)<\/td>\n<td>Electric channel is 2 ports<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>6433F Lightwave Component Analyzer (four ports)<\/td>\n<td>Electric channel is 4 ports<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>6433H Lightwave Component Analyzer (dual port)<\/td>\n<td>Electric channel is 2 ports<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>6433H Lightwave Component Analyzer (four ports)<\/td>\n<td>Electric channel is 4 ports<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>6433L Lightwave Component Analyzer (dual port)<\/td>\n<td>Electric channel is 2 ports<\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>6433L Lightwave Component Analyzer (four ports)<\/td>\n<td>Electric channel is 4 ports<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<ul>\n<li>Lists:<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<div class=\"rich-text-table\">\n<table width=\"1323\">\n<tbody>\n<tr>\n<td><b>No.<\/b><\/td>\n<td><b>Name<\/b><\/td>\n<td><b>Description<\/b><\/td>\n<\/tr>\n<tr>\n<td>1<\/td>\n<td>Power Cord Assembly<\/td>\n<td>Standard three-core power cord<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>User Manual<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Product Certification<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>Metrology Level of Fiber Jumper<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>RF Cable<\/td>\n<td>2 (corresponding interface: one female and one male)<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>USB Cable<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Ceyear 6433 series Lightwave Component Analyzers includes 6433D (10MHz ~ 20GHz), 6433F (10MHz ~ 43.5GHz), 6433H (10MHz ~ 50GHz), 6433L (10MHz ~ 67GHz). The 6433 series is the latest solution\u00a0to\u00a0characteristic\u00a0test\u00a0of\u00a0high-speed\u00a0electro\u00a0&#8211;\u00a0optical\u00a0(E\/O)\u00a0devices,\u00a0optical\u00a0&#8211;\u00a0electro\u00a0(O\/E)\u00a0devices, and optical &#8211; optical (O\/O) devices. The modulation frequency range covers 10MHz~67GHz. It supports different frequency range, frequency interval, IF bandwidth setting. The minimum frequency resolution is up to\u00a01Hz.<br \/>\nCeyear 6433 series LCA adopts an integrated design scheme that realizes a one-click fast broadband frequency sweep test based on broadband hardware optimization design, building network error model, and utilization of core calibration algorithm. It is mainly used for the test of bandwidth, amplitude-frequency response, phase-frequency response, group delay and other parameters of core electro &#8211; optical devices. (electro-optical modulator, direct modulated laser, light-transmitting components), electro-optical devices (PIN optoelectronic detector, APD optoelectronic detector, light-receiving components), optical &#8211; optical devices (passive devices such as fiber filter) in the modern high-speed light transmission system.<\/p>\n<p><a href=\"https:\/\/www.keisokuten.jp\/file.php?id=11906\">Download DataSheet<\/a><\/p>\n","protected":false},"featured_media":32828,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[1983,40],"product_tag":[2102,2105,2103,2104],"class_list":{"0":"post-32827","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ceyear","7":"product_cat-rf-microwave","8":"product_tag-ceyear-6433d-f-h-l-lightwave-component-analyzer-10mhz-20ghz-43-5ghz-50ghz-67ghz","9":"product_tag-ceyear-component-analyzer-10mhz-20ghz-43-5ghz-50ghz-67ghz","10":"product_tag-ceyear-lightwave-component-analyzer-10mhz-20ghz-43-5ghz-50ghz-67ghz","11":"product_tag-lightwave-component-analyzer-10mhz-20ghz-43-5ghz-50ghz-67ghz","13":"first","14":"instock","15":"shipping-taxable","16":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product\/32827","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/comments?post=32827"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/media\/32828"}],"wp:attachment":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/media?parent=32827"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_brand?post=32827"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_cat?post=32827"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_tag?post=32827"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}