{"id":32799,"date":"2024-06-05T08:28:10","date_gmt":"2024-06-05T08:28:10","guid":{"rendered":"https:\/\/coral-i.co.za\/test-equipment\/?post_type=product&#038;p=32799"},"modified":"2024-06-05T08:28:10","modified_gmt":"2024-06-05T08:28:10","slug":"ceyear-3986-series-noise-figure-analyzer","status":"publish","type":"product","link":"https:\/\/coral-i.co.za\/test-equipment\/product\/ceyear-3986-series-noise-figure-analyzer\/","title":{"rendered":"Ceyear 3986 Series Noise Figure Analyzer"},"content":{"rendered":"<div class=\"solute_sec\">\n<h4 class=\"functional\">FUNCTIONS &amp; FEATURES<\/h4>\n<div class=\"product-gntd-box\">\n<ul class=\" list-paddingleft-2\">\n<li>Wide-range coverage<\/li>\n<li>High-sensitivity reception and high-precision test performance<\/li>\n<li>Amplifier, Up converter and Down converter measuring mode<\/li>\n<li>Single sideband and double sideband measuring function<\/li>\n<li>Comprehensive loss compensation function<\/li>\n<li>Flexible document and excel processing functions<\/li>\n<li>Passed\/failed test notification limiting line function<\/li>\n<li>Various external interfaces<\/li>\n<li>Dual noise source drive<\/li>\n<\/ul>\n<p><strong>Wide-range<\/strong><strong>coverage<\/strong><\/p>\n<p>The coaxial integrated frequency of 3986 series noise figure analyzer covers the range of 10 MHz\uff5e50 GHz. 5 frequency band configurations are selectable for user&#8217;s different test demands. , The upper frequency limit of the spread spectrum measurement capacity can be expanded to 110 GHz (with an external MMW spread spectrum module).<\/p>\n<p><strong>High-sensitivity reception and high-precision test performance<\/strong><\/p>\n<p>The optimum reception sensitivity reaches up to -170 dBm\/Hz, and full band reception sensitivity precedes-162 dBm\/Hz. The breakthrough in automatic modulation and precise calibration technology of large scale channel gains in the whole instrument. Linearity within the range of noise power measurement precedes \u00b10.1 dB.<\/p>\n<p><strong>Chinese and English operation interface with dual-channel HD display<\/strong><\/p>\n<p>Chinese and English operation interface with 10.1-inch LCD monitor that can be displayed in three forms, i.e. diagrams, excels and tester display. In the form of diagram display, it can display the measurement results combination of two random parameters, such as noise figure, Y factor, gain, equivalent input noise temperature, changing with the frequency.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"https:\/\/i0.wp.com\/cc-globaltech.com\/wp-content\/uploads\/2019\/06\/3986-a-1.jpg?resize=1010%2C440\" alt=\"3986H Noise Figure Analyzer (10 MHz\uff5e50 GHz)\" width=\"702\" height=\"306\" \/><\/p>\n<p><strong>Amplifier, up converter and down converter measuring mode<\/strong><\/p>\n<p>With multiple measurements modes, 3986 series Noise Figure Analyzers can be used to test noise figure and gain measuring of DUT as well as support the measurement of automatic gain scanning and noise figure of multistage frequency reception links reception link.\u00a0Intuitive user interface makes easy setting of various measurements.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/i0.wp.com\/cc-globaltech.com\/wp-content\/uploads\/2019\/06\/3986-h.png?fit=600%2C276&amp;ssl=1\" alt=\"3986H Noise Figure Analyzer (10 MHz\uff5e50 GHz)\" \/><\/p>\n<p><strong>Single sideband and double sideband measuring function<\/strong><\/p>\n<p>It has the capacity of setting, controlling and data processing for the measurement of single sideband (including upper sideband and lower sideband) and double sideband. During noise figure measurement, the setting of the sideband must be the same as that is actually applied by the measured subject.<\/p>\n<p><strong>Comprehensive loss compensation functions<\/strong><\/p>\n<p>Loss in the channel can be compensated by means of fixed or excel form before and after the measurement, which would greatly benefit precise measurement of noise figure of automatic test system or microwave chips.<\/p>\n<p><strong>Flexible document and excel processing functions<\/strong><\/p>\n<p>The types of documents and excels that can be processed by 3986 Series Noise Figure Analyzers include limit lines, excess noise ratio table, track lines, instrument status, frequency list, loss compensation table and screen images. For user data process purposes, documents and excels can be edited, saved, pulled and deleted.<\/p>\n<p><strong>Passed\/failed test notification limit line function<\/strong><\/p>\n<p>Limit line function of test passed\/failed notification simplifies passed\/failed test for the use of production line. Types of limit lines include upper limits and lower limits. A pair of upper and lower limit lines could be set individually for each display channel. When measurement results exceed limit range, the instrument would prompt &#8220;Limit Line Failed&#8221; notification in red.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Various external interfaces<\/strong><\/p>\n<p>Various external interfaces enable high re-usability. Smart interfaces like GP-IB, LAN, USB and VGA can enable user function extension and reconstruction of the system.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Dual noise source drive<\/strong><\/p>\n<p>Standard and smart noise source drive interfaces provided. Standard noise source drive interface that provides\u00a0+28\u00a0V pulse drive voltage to support\u00a0noise sources from multiple manufacturers. It&#8217;s highly compatible. Smart noise source drive interface is also compatible with Keysight N4000 series smart noise sources. Noise figure analyzer can identify the connection of smart noise source and load excess noise ratio data automatically. It can also detect changes of environment temperature for temperature correction of noise figure to improve speed and accuracy of measurement.<\/p>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<div class=\"solute_sec\">\n<h4 class=\"functional\">TYPICAL APPLICATIONS<\/h4>\n<div class=\"product-dxyy-box\">\n<p><strong>Basic amplifier measurement application<\/strong><\/p>\n<p>Basic amplifier measurement is the most common measurement mode. It&#8217;s used for noise figure and gain measurement of measured subjects without frequency conversion (including active or passive linear units or systems like amplifiers, filters, and isolators).<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Down converter mode measurement application<\/strong><\/p>\n<p>Down converter mode of the system is focused on spread spectrum measurement of amplifier measured subjects. When the frequency range of an amplifier measured subject exceeds that of the noise figure analyzer, spread spectrum measurement of the noise figure is realized by external mixer. External mixer is used during calibration and measurement as a part of the test system. To reduce the uncertainty of noise figure measurement, frequency conversion loss and noise figure of the chosen mixer should be as small as possible. Besides, the intermediate frequency output interface of the mixer should be well isolated to local oscillation signals.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Up and down converter measurement application<\/strong><\/p>\n<p>The measured subject is an up and down converter installation, up converter and transmitter or down converter and receiver for instance, then the output intermediate frequency would be in the working frequency range of the noise figure analyzer. During up and down converter measurement, 3986 series Noise Analyzer provides two modes of settings, fixed intermediate frequency, variable local oscillation and fixed local oscillation, variable intermediate frequency, which are used for RF response characters and intermediate frequency response characters, respectively.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Technical Specifications (spec.):\u00a0<\/strong>Unless clarified otherwise, calibrated instruments shall be placed within working temperature ranged from 0\u00b0C to 40\u00b0C for at least two hours before warming up for 30 minutes to ensure performance. Including uncertainty of measurement. Unless clarified otherwise, data included herein are technical indicators.<\/p>\n<p><strong>Typical Value (typ.):\u00a0<\/strong>indicates that 80% instruments can reach typical performance. The data is not assurance data and doesn&#8217;t include uncertain factors during measurement. It&#8217;s only valid under 25\u00b0C room temperature.<\/p>\n<p><strong>Nominal Value (nom.):<\/strong>\u00a0indicates anticipated average performance, and performances can&#8217;t be tested through designed performance features or limited test means. Such as 50 \u03a9 connectors. Product performance labeled as nominal value is not included in product warranty. It is measured under room temperature (around 25\u00b0C).<\/p>\n<p><strong>Measured Value (meas.):<\/strong>\u00a0indicates, to compare with anticipated performance, performance features measured during design stage. Such as amplitude drift variable through time. The data is not assurance data and is measured under room temperature (around 25\u00b0C).<\/p>\n<p>Table 1 Technical Specifications<\/p>\n<table>\n<thead>\n<tr class=\"firstRow\">\n<td colspan=\"2\" valign=\"top\"><strong>Major Technical Specifications<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td width=\"362\"><strong>Frequency \u00a0 Range<\/strong><\/td>\n<td width=\"617\">10 MHz\uff5e4 GHz\/18 GHz\/26.5 GHz\/40 GHz\/50 GHz<\/td>\n<\/tr>\n<tr>\n<td width=\"362\"><strong>Accuracy \u00a0 of Frequency Reference<\/strong><\/td>\n<td valign=\"top\" width=\"617\">Precedes\u00b1&lt;0.2ppm \u00a0 (23\u2103\u00b13\u2103)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"356\"><strong>Accuracy \u00a0 of Frequency Tuning<\/strong><\/td>\n<td width=\"617\">Precedes\u00b1&lt; (Reference frequency \u00a0 error +100 kHz) 10 MHz\uff5e4 GHz<\/td>\n<\/tr>\n<tr>\n<td width=\"374\">Precedes\u00b1&lt; (Reference frequency \u00a0 error +400 kHz) 4 GHz\uff5e18\/26.5\/40\/50 GHz<\/td>\n<\/tr>\n<tr>\n<td width=\"362\"><strong>Noise \u00a0 Figure Measuring Range<\/strong><\/td>\n<td width=\"617\">0\uff5e30 \u00a0 dB (ENR:\u00a012 dB\uff5e17 \u00a0 dB)<\/td>\n<\/tr>\n<tr>\n<td width=\"362\"><strong>Noise \u00a0 Figure Measuring Uncertainty<\/strong><\/td>\n<td width=\"617\">Precedes\u00b1&lt;0.1 dB<\/td>\n<\/tr>\n<tr>\n<td width=\"362\"><strong>Gain \u00a0 Measuring Range<\/strong><\/td>\n<td width=\"617\">-20 dB\uff5e+40 \u00a0 dB<\/td>\n<\/tr>\n<tr>\n<td width=\"362\"><strong>Gain \u00a0 Measuring Uncertainty<\/strong><\/td>\n<td width=\"617\">Precedes\u00b1&lt;0.17 dB<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" width=\"362\"><strong>Input \u00a0 Interface SWR<\/strong><\/td>\n<td width=\"617\">&lt;1.90: 1\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 10 MHz\u2264f\u22644 GHz<\/td>\n<\/tr>\n<tr>\n<td width=\"374\">&lt;2.10: 1\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 4 GHz&lt;f\u226418 GHz<\/td>\n<\/tr>\n<tr>\n<td width=\"374\">&lt;2.40: 1\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 18 GHz&lt;f\u226426.5 GHz<\/td>\n<\/tr>\n<tr>\n<td width=\"374\">&lt;2.40: 1\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 26.5 GHz&lt;f\u226440 GHz<\/td>\n<\/tr>\n<tr>\n<td width=\"374\">&lt;2.40: 1\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 40 GHz&lt;f\u226450 GHz<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" width=\"362\"><strong>Local \u00a0 Noise Figure<\/strong><\/td>\n<td width=\"617\">&lt;8.0 dB\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 10 MHz\u2264f\u22644 GHz<\/td>\n<\/tr>\n<tr>\n<td width=\"374\">&lt;7.5 dB\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 4 GHz&lt;f\u226418 GHz<\/td>\n<\/tr>\n<tr>\n<td width=\"374\">&lt;8.0 dB\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 18 GHz&lt;f\u226426.5 GHz<\/td>\n<\/tr>\n<tr>\n<td width=\"374\">&lt;10.0 dB\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 26.5 GHz&lt;f\u226440 GHz<\/td>\n<\/tr>\n<tr>\n<td width=\"374\">&lt;12.0 dB\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 40 GHz&lt;f\u226450 GHz<\/td>\n<\/tr>\n<tr>\n<td width=\"362\"><strong>Jitter \u00a0 (uneven)<\/strong><\/td>\n<td width=\"617\">&lt;0.17 dB\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0(Y Factor\u00a0\u00a0 Typical Value 5 dB)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"362\"><strong>Noise \u00a0 source drive voltage<\/strong><\/td>\n<td width=\"617\">&lt;1.0\u00a0V\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Noise source \u00a0 off<\/td>\n<\/tr>\n<tr>\n<td width=\"412\">+28.0\u00b10.10\u00a0V\u00a0\u00a0\u00a0\u00a0 Noise source \u00a0 on<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Table2 Product Features<\/p>\n<table>\n<thead>\n<tr class=\"firstRow\">\n<td colspan=\"3\" valign=\"top\" width=\"787\"><strong>General Technical Specifications<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"254\"><strong>Temperature \u00a0 Range<\/strong><\/td>\n<td valign=\"top\" width=\"423\">During operation: 0\uff5e+40\u2103<\/p>\n<p>During storage: -40\uff5e+70\u2103<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"254\"><strong>Elevation \u00a0 above sea level<\/strong><\/td>\n<td valign=\"top\" width=\"423\">4, 600 \u00a0 meters<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"254\"><strong>Electromagnetic \u00a0 compatibility<\/strong><\/td>\n<td width=\"423\">Comply with \u00a0 the following requirements of GJB 3947A-2009 provision 3.9.2:<\/p>\n<p>a) Conducted \u00a0 emission through CE102 power cable;<\/p>\n<p>b) \u00a0\u00a0\u00a0Conducted susceptibility of CS101 power \u00a0 cable;<\/p>\n<p>c) \u00a0\u00a0\u00a0Conducted susceptibility injected by CS114 \u00a0 harness;<\/p>\n<p>d) Radiated \u00a0 emission through RE102 electric field;<\/p>\n<p>e) Radiated \u00a0 susceptibility through RS103 electric field.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"254\"><strong>Safety<\/strong><\/td>\n<td width=\"423\">Comply with \u00a0 safety certificate requirements of GJB 3947A-2009 provision 3.10.<\/p>\n<p>a) \u00a0\u00a0The \u00a0 resistance between power input end and the chassis (power switch on engaged \u00a0 position) shall be no less than100\u00a0M\u03a9 \u00a0 under standard atmosphere pressure and no less than 2\u00a0M\u03a9 in damp environment.<\/p>\n<p>b) Apply \u00a0 1500\u00a0VAC between \u00a0 power input end and the chassis, no phenomena like breakdown, flash-over and \u00a0 flicker shall happen.<\/p>\n<p>c) In \u00a0 operation, leakage current between chassis and ground shall be no more than \u00a0 3.5\u00a0mA.<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"77\"><strong>Power \u00a0 requirements<\/strong><\/td>\n<td width=\"137\"><strong>Voltage \u00a0 and frequency (nominal value)<\/strong><\/td>\n<td width=\"423\">220\u00a0V, 50\u00a0Hz;<\/p>\n<p>Allowed \u00a0 range for steady voltage is\u00a0\u00b110% \u00a0 of the nominal value, allowed range for steady frequency is\u00a0\u00b15% of the nominal \u00a0 value<\/p>\n<p>&nbsp;<\/td>\n<\/tr>\n<tr>\n<td width=\"232\"><strong>Power \u00a0 dissipation<\/strong><\/td>\n<td width=\"657\">Max. power \u00a0 dissipation: 250\u00a0W<\/p>\n<p>Max. standby: \u00a0 20\u00a0W<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"254\"><strong>Monitor<\/strong><\/td>\n<td valign=\"top\" width=\"423\">1280\u00d7800, XGA<\/p>\n<p>10.1&#8243;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"254\"><strong>Data \u00a0 storage<\/strong><\/td>\n<td width=\"423\">160\u00a0G solid state disk<\/p>\n<p>Support USB \u00a0 2.0 standard storage units<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"254\"><strong>Weight<\/strong><\/td>\n<td width=\"423\">Net weight: less \u00a0 than23\u00a0kg;<\/p>\n<p>Packaged \u00a0 shipping weight: 34\u00a0kg \u00a0 nominal value<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"254\"><strong>Size<\/strong><\/td>\n<td width=\"423\">Width\u00d7Height\u00d7Depth \u00a0 (mm)=426\u00d7177\u00d7460 (handle, bottom, pad and side strap excluded), allowed \u00a0 tolerance \u00b110\u00a0mm.<\/p>\n<p>Width\u00d7Height\u00d7Depth \u00a0 (mm)=510\u00d7190\u00d7534 (handle, bottom, pad and side strap included), allowed \u00a0 tolerance \u00b110\u00a0mm.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"254\"><strong>Warranty<\/strong><\/td>\n<td width=\"423\">3986 Series \u00a0 Noise Figure Analyzer is under a standard warranty of 18 months.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"254\"><strong>Reliability<\/strong><\/td>\n<td width=\"423\">MTBF (\u03b8<sub>0<\/sub>) \u00a0 \u22655000\u00a0h<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"254\"><strong>Calibration \u00a0 interval<\/strong><\/td>\n<td valign=\"top\" width=\"423\">A \u00a0 calibration interval of one year is recommended. Calibration service shall be \u00a0 provided by professional calibration institutions.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Table3 Front Panel Interfaces<\/p>\n<table width=\"1005\">\n<thead>\n<tr class=\"firstRow\">\n<td colspan=\"3\"><strong>Front Panel Interfaces<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td rowspan=\"5\" width=\"262\"><strong>RF \u00a0 input interface<\/strong><\/td>\n<td width=\"398\">3986A<\/td>\n<td width=\"262\">3.5\u00a0mm (m)<\/td>\n<\/tr>\n<tr>\n<td width=\"398\">3986D<\/td>\n<td width=\"262\">3.5\u00a0mm (m)<\/td>\n<\/tr>\n<tr>\n<td width=\"398\">3986E<\/td>\n<td width=\"262\">3.5\u00a0mm (m)<\/td>\n<\/tr>\n<tr>\n<td width=\"398\">3986F<\/td>\n<td width=\"262\">2.4\u00a0mm (m)<\/td>\n<\/tr>\n<tr>\n<td width=\"398\">3986H<\/td>\n<td width=\"344\">2.4\u00a0mm (m)<\/td>\n<\/tr>\n<tr>\n<td width=\"344\"><strong>Standard \u00a0 noise source drive output<\/strong><\/td>\n<td colspan=\"2\">BNC female adapter<\/td>\n<\/tr>\n<tr>\n<td width=\"undefined\"><strong>Smart \u00a0 noise source drive output<\/strong><\/td>\n<td colspan=\"2\">Multi-core connector<\/td>\n<\/tr>\n<tr>\n<td width=\"undefined\"><strong>USB2.0 \u00a0 interface<\/strong><\/td>\n<td colspan=\"2\">For connecting mouse, keyboard, and \u00a0 updating software and backing up data.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>Table\u00a04 Back Panel Interfaces<\/p>\n<table>\n<tbody>\n<tr class=\"firstRow\">\n<td colspan=\"2\"><strong>Back Panel Interfaces<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"314\"><strong>Keyboard \u00a0 interface<\/strong><\/td>\n<td width=\"665\">Standard PS\/2 \u00a0 interface for connecting standard computer keyboard.<\/td>\n<\/tr>\n<tr>\n<td width=\"314\"><strong>Video \u00a0 interface<\/strong><\/td>\n<td width=\"665\">VGA \u00a0 interface (15-core D-SUB adapter) for connecting monitors<\/td>\n<\/tr>\n<tr>\n<td width=\"314\"><strong>LAN \u00a0 interface<\/strong><\/td>\n<td width=\"665\">StandardRJ-45 \u00a0 type, 1000Base-T for software update and remote control<\/td>\n<\/tr>\n<tr>\n<td width=\"314\"><strong>GP-IB \u00a0 Interface<\/strong><\/td>\n<td width=\"665\">IEEE-488 Bus connector, 24-pin plug (GP-IB \u00a0 code: SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, C0) for remote control<\/td>\n<\/tr>\n<tr>\n<td width=\"314\"><strong>USB2.0 \u00a0 interface<\/strong><\/td>\n<td width=\"665\">For connecting mouse, keyboard, and updating \u00a0 software and backing up data.<\/td>\n<\/tr>\n<tr>\n<td width=\"314\"><strong>10 \u00a0 MHz reference input<\/strong><\/td>\n<td width=\"665\">50\u00a0\u03a9 \u00a0 impedance, BNC female adapter, amplitude range -5 dBm\uff5e+10 \u00a0 dBm<\/td>\n<\/tr>\n<tr>\n<td width=\"314\"><strong>10 \u00a0 MHz reference output<\/strong><\/td>\n<td width=\"665\">50\u00a0\u03a9 \u00a0 impedance, BNC female adapter, output amplitude \u22650 dBm<\/td>\n<\/tr>\n<tr>\n<td width=\"314\"><strong>Trigger \u00a0 input<\/strong><\/td>\n<td width=\"665\">BNC female adapter<\/td>\n<\/tr>\n<tr>\n<td width=\"314\"><strong>Trigger \u00a0 output1<\/strong><\/td>\n<td width=\"665\">BNC female adapter<\/td>\n<\/tr>\n<tr>\n<td width=\"314\"><strong>Trigger \u00a0 output2<\/strong><\/td>\n<td width=\"665\">BNC female adapter<\/td>\n<\/tr>\n<tr>\n<td width=\"308\"><strong>Detection \u00a0 output<\/strong><\/td>\n<td width=\"NaN\">BNC female adapter<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>3986 Series Noise Figure Analyzers include 3986A (10 MHz\uff5e4 GHz), 3986D (10 MHz\uff5e18 GHz), 3986E (10 MHz\uff5e26.5 GHz), 3986F (10 MHz\uff5e40 GHz) and 3986H (10 MHz\uff5e50 GHz). Features of the product include wide-range frequency coverage, high-sensitivity reception, friendly user interface, big screen dual channel HD display, various external interfaces, and dual noise source drive etc.<\/p>\n<p>It can measure the noise figure and gain of amplifiers, up converters and down converters, as well as to support automatic measurement of noise figure of multi-stage converters. Guide interfaces are intuitive for setting measurement modes. The comprehensive loss compensation function can compensate loss induced in measurement channel before and\/or after the device under test by means of fixed or table forms.<\/p>\n<p>The built-in noise figure measurement uncertainty calculator does quantitative analysis of the uncertainty of measurement noise figure. Limit line function that provides test passed\/failed notification simplifies the determination of passed\/failed test.<\/p>\n<p>User friendly features make it easy for engineering technicians to set measurements correctly, to observe and save measurement results in different forms. They can be widely used in R&amp;D, manufacturing, testing and technical assurance tests of electronic equipment for communication etc.<\/p>\n<p>&nbsp;<\/p>\n<h5><a href=\"http:\/\/ceyear.co.za\/wp-content\/uploads\/2022\/08\/3986-Series-Noise-Figure-Analyzer-Datasheet.pdf\">3986 Series Noise Figure Analyzer Datasheet<\/a><\/h5>\n<p><a href=\"http:\/\/ceyear.co.za\/wp-content\/uploads\/2022\/08\/3986-Series-Noise-Figure-Analyzer-User-Manual.pdf\">3986 Series Noise Figure Analyzer User Manual<\/a><\/p>\n","protected":false},"featured_media":32800,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[1983,40],"product_tag":[2066,2064,2063,2065],"class_list":["post-32799","product","type-product","status-publish","has-post-thumbnail","product_cat-ceyear","product_cat-rf-microwave","product_tag-ceyear-3986","product_tag-ceyear-3986-noise-figure-analyzer","product_tag-ceyear-3986-series-noise-figure-analyzer","product_tag-noise-figure-analyzer","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product\/32799","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/comments?post=32799"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/media\/32800"}],"wp:attachment":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/media?parent=32799"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_brand?post=32799"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_cat?post=32799"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_tag?post=32799"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}