{"id":32746,"date":"2024-06-05T08:00:39","date_gmt":"2024-06-05T08:00:39","guid":{"rendered":"https:\/\/coral-i.co.za\/test-equipment\/?post_type=product&#038;p=32746"},"modified":"2024-06-05T08:00:39","modified_gmt":"2024-06-05T08:00:39","slug":"ceyear-4041d-e-f-g-spectrum-analyzer","status":"publish","type":"product","link":"https:\/\/coral-i.co.za\/test-equipment\/product\/ceyear-4041d-e-f-g-spectrum-analyzer\/","title":{"rendered":"Ceyear 4041D\/E\/F\/G Spectrum Analyzer"},"content":{"rendered":"<div class=\"solute_sec\">\n<h4 class=\"functional\">FUNCTIONS &amp; FEATURES<\/h4>\n<div class=\"product-gntd-box\">\n<ul class=\" list-paddingleft-2\">\n<li>A portable case characterized by thin thickness and light weight, which can be conveniently placed and carried<\/li>\n<li>Wide frequency range covering 9kHz~20GHz\/26.5GHz\/32GHz\/44GHz; with the full-band pre-amplifier as standard<\/li>\n<li>Low displayed average noise level: -163dBm@1Hz RBW(typical)<\/li>\n<li>Excellent phase noise performance: -106dBc\/Hz@100kHz frequency offset@1GHz carrier<\/li>\n<li>RBW: 1Hz~10MHz<\/li>\n<li>Extremely high sweep speed: for 1GHz span, shortest sweep time &lt;20ms<\/li>\n<li>Various measurement functions, such as the channel power, occupied bandwidth, adjacent channel power, audio demodulation, carrier-to-noise ratio, and emission mask<\/li>\n<li>Abundant test function mode options: interference analysis (spectrogram plot, RSSI), analog AM\/FM\/PM analyzer, channel scanner, and high-precision power meter, etc.<\/li>\n<li>Easy to operate, equipped with 12.1-inch high brightness LCD screen featuring large font display and loose button layout, and supporting the capacitive touch screen operation and touch screen cursor dragging<\/li>\n<li>Good Single-Sideband Phase Noise Indicators<\/li>\n<li>As the multi-loop phase-locked frequency synthesis technology is adopted, the whole frequency band has good phase noise indicators.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong>High Receiving Sensitivity<\/strong><\/p>\n<p>The miniaturization integrated design technology of microwave &amp; millimeter-wave frequency conversion modules and the use of the low noise preamplifier in the whole frequency band reduce the noise level and improve the receiving sensitivity.<\/p>\n<p>10 MHz~20 GHz typical receiving sensitive value-160 dBm\/Hz (preamplifier on)<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Comprehensive Spectrum Measurement Functions<\/strong><\/p>\n<p>It has functions including the signal tracking, peak tracking and signal search.<\/p>\n<p>It can provide 12 cursors, and it has both normal mode and differential mode for option, and supports the noise marker and frequency count functions.<\/p>\n<p>The transmitter power kit has the one-button measurement functions, including the channel power, occupied bandwidth, adjacent channel power, carrier-to-noise ratio, emission mask, and audio demodulation.<\/p>\n<p>3 display traces and 6 detection modes are available.<\/p>\n<p>It supports to sweep, edit, store and call the list.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Various Measurement Functions<\/strong><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Convenient\u00a0and Fast User Experience<\/strong><\/p>\n<p>One-button quick measurement<\/p>\n<p>State and data storage and call functions<\/p>\n<p>12.1-inch high brightness LCD display screen, less light transmittance, and clear display<\/p>\n<p>Convenient capacitive touch screen<\/p>\n<p>Supporting a number of auxiliary interfaces including the USB program control and storage, LAN program control, VGA video output, zero span IF output, and trigger input, convenient for the user\u2019s operation<\/p>\n<\/div>\n<\/div>\n<div class=\"solute_sec\">\n<h4 class=\"functional\">TYPICAL APPLICATIONS<\/h4>\n<div class=\"product-dxyy-box\">\n<p><strong>Test of Components and Parts<\/strong><\/p>\n<p>It can be used for the test of parameters and indicators including the gain, frequency response, frequency conversion loss and insertion loss of the components and modules including the amplifier, filter, mixer, attenuator, cable and directional coupler.<\/p>\n<p><strong>Test and Diagnosis of the Transmitter and Receiver<\/strong><\/p>\n<p>The 4041 spectrum analyzer has a number of measurement function modes including the spectrum analyzer, interference analyzer, AM\/FM\/PM analyzer, power meter, and channel scanner, and it also has a number of measurement functions including the channel power, occupied bandwidth, adjacent channel power, carrier-to-noise ratio, field strength, and emission mask; therefore, it can provide the comprehensive spectrum analysis and diagnosis service for the test of the transmitter and receiver.<\/p>\n<\/div>\n<table width=\"1282\">\n<tbody>\n<tr class=\"firstRow\">\n<td width=\"308\"><strong>Model<\/strong><\/td>\n<td width=\"610\">4041D\/E\/F\/G<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Frequency range<\/td>\n<td width=\"610\">4041D: 9kHz~20GHz\u00a0\u00a0\u00a0\u00a0\u00a0 \u00a0 4041E: 9kHz~26.5GHz<\/p>\n<p>4041F: 9kHz~32GHz\u00a0\u00a0\u00a0\u00a0\u00a0 \u00a0 4041G: 9kHz~44GHz<\/p>\n<p>Tuning resolution: 1 Hz<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Frequency reference<\/td>\n<td width=\"610\">Nominal frequency:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 10MHz<\/p>\n<p>Frequency reference error:\u00a0\u00b1\u00a0\u00a0 (Last calibration date \u00d7 aging rate + temperature stability + calibration \u00a0 accuracy)<\/p>\n<p>Aging rate:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00b15\u00b410<sup>-7<\/sup>\/year<\/p>\n<p>Temperature stability:\u00a0\u00a0\u00a0\u00a0\u00b11\u00b410<sup>-7<\/sup>(0\u00b0C \u00a0\u00a0~\u00a0\u00a0 50\u00b0C, relative to 25\u00b15\u00b0C)<\/p>\n<p>Initial calibration accuracy:\u00a0\u00b13\u00b410<sup>-7<\/sup><\/p>\n<p>Note: The default time elapsed since the last \u00a0 calibration date is one year.<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Frequency readout accuracy<\/td>\n<td width=\"610\">Frequency readout accuracy = \u00b1 (frequency reading \u00a0 \u00d7 frequency reference error +2% \u00d7 sweep width +10% \u00d7 resolution bandwidth)<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Frequency span<\/td>\n<td width=\"610\">Range: 100Hz\uff5eupper \u00a0 frequency limit of corresponding model or 0Hz<\/p>\n<p>Accuracy: \u00b12.0%<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Sweep time<\/td>\n<td width=\"610\">Range: 10\u03bcs~600s (zero span);<\/p>\n<p>Accuracy: \u00b12.00% (zero span)<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Resolution bandwidth<\/td>\n<td width=\"610\">Range: 1Hz~10MHz (step by 1-3)<\/p>\n<p>Accuracy (3.0dB): \u00b110%\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 1kHz~3MHz<\/p>\n<p>\u00b120%\u00a0\u00a0\u00a0 \u00a0\u00a0\u00a010MHz<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Resolution bandwidth change to uncertainty<\/td>\n<td width=\"610\">\u00b11.20dB\u00a0\u00a0\u00a0 \u00a0 1Hz~10MHz (take 100kHz RBW as a reference)<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Video bandwidth<\/td>\n<td width=\"610\">1Hz~10MHz (1-3 times step)<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Detection mode<\/td>\n<td width=\"610\">Normal, Peak, Neg Peak, Sample, Average, RMS<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Single-sideband phase noise<\/p>\n<p>(Carrier wave 1GHz, 20\u2103~30\u2103)<\/td>\n<td width=\"610\">\u2264-102dBc\/Hz@10kHz frequency offset<\/p>\n<p>\u2264-106dBc\/Hz@100kHz frequency offset<\/p>\n<p>\u2264-111dBc\/Hz@1MHz frequency offset<\/p>\n<p>\u2264-123dBc\/Hz@10MHz frequency offset<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Average noise level display<\/p>\n<p>(50\u03a9 load at the input end, 0dB input attenuation, \u00a0 average detector mode, logarithmic Video Type, RBW normalization to 1Hz, \u00a0 20-30\u00b0C)<\/td>\n<td width=\"610\">Preamplifier off<\/p>\n<p>\u2264-138dBm (10MHz~20GHz)\u00a0 \u2264-135dBm (20GHz~32GHz)<\/p>\n<p>\u2264-127dBm (32GHz~40GHz)\u00a0 \u2264-120dBm (40GHz~44GHz)<\/p>\n<p>Preamplifier on<\/p>\n<p>\u2264-157dBm (10MHz~20GHz)\u00a0 \u2264-154dBm (20GHz~32GHz)<\/p>\n<p>\u2264-148dBm (32GHz~40GHz)\u00a0 \u2264-140dBm (40GHz~44GHz)<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Residual response<\/p>\n<p>(RF input match, 0dB attenuation)<\/td>\n<td width=\"610\">(Exceptional frequency: 3200MHz)<\/p>\n<p>Preamplifier off<\/p>\n<p>\u2264-90 dBm (10MHz~13GHz)\u00a0\u00a0 \u2264-85 dBm (13GHz~20GHz)<\/p>\n<p>\u2264-80 dBm (20GHz~44GHz)<\/p>\n<p>Preamplifier on<\/p>\n<p>\u2264-100 dBm (10MHz~32GHz)\u00a0\u00a0 \u2264-95 dBm (32GHz~44GHz)<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Second harmonic distortion<\/td>\n<td width=\"610\">&lt;-60dBc (0dB attenuation, -30dBm input signal)<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">1dB gain compression<\/p>\n<p>(Double-tone test, 10MHz signal spacing)<\/td>\n<td width=\"610\">\u2265-2dBm\u00a0 \u00a0 50MHz~4GHz<\/p>\n<p>\u2265-3dBm\u00a0 4GHz~13GHz<\/p>\n<p>\u2265-3dBm\u00a0 \u00a0 13GHz~44GHz<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">3-order intermodulation distortion<\/p>\n<p>(-25dBm double-tone signal, 100kHz spacing, 0dB \u00a0 attenuation, pre-amplifier off)<\/td>\n<td width=\"610\">\u2265+7dBm\u00a0 \u00a0 50MHz~4GHz<\/p>\n<p>\u2265+6dBm\u00a0 \u00a0 4GHz~13GHz<\/p>\n<p>\u2265+6dBm\u00a0 \u00a0 13GHz~44GHz<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Total level uncertainty<\/p>\n<p>(frequency range 10MHz~40GHz, input signal \u00a0 -10~-50dBm, all settings are auto couple, 20\u00b0C ~30\u00b0C)<\/td>\n<td width=\"610\">\u00b11.80dB\uff0810MHz~13GHz\uff09<\/p>\n<p>\u00b12.30dB\uff0810MHz\uff5e40GHz\uff09<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Input attenuator<\/td>\n<td width=\"610\">Scope of attenuation 0dB~50dB, 10dB step<\/p>\n<p>Conversion uncertainty: \u00b11.20dB<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Maximum safe input level<\/td>\n<td width=\"610\">+30dBm, typical value (\u226510dB attenuation)<\/p>\n<p>+23dBm, typical value (&lt;10dB attenuation)<\/p>\n<p>+13dBm, typical value (preamplifier ON)<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Reference level<\/td>\n<td width=\"610\">Range: Logarithmic scale -120dBm~+30dBm, 1dB step<\/p>\n<p>Linear scale: 22.36\u03bcV~7.07V, 0.1% step<\/p>\n<p>Conversion error: \u00b11.20dB (reference level 0dBm \u00a0 ~-60dBm)<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Displayed scale<\/td>\n<td width=\"610\">Logarithmic scale: 0.1dB~10dB per scale, minimum \u00a0 0.1dB step, 10-scale display<\/p>\n<p>Linear scale: 10-scale display<\/p>\n<p>Calibration unit: V, A, W, dBm, dBW, dBV, dBmV, dBuV, \u00a0 dBA, dBmA, dBuA<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Scale fidelity<\/td>\n<td width=\"610\">\u00b11.00 dB<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Size<\/td>\n<td width=\"610\">430mm(width) \u00d7 270mm (height) \u00d7 180mm (depth) \u00a0 (excluding the handle and foot)<\/p>\n<p>430mm(width) \u00d7 360mm (height) \u00d7 180mm (depth) \u00a0 (including the handle and foot)<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Weight<\/td>\n<td width=\"610\">\u226412 kg<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Power supply<\/td>\n<td width=\"610\">AC 220\/240V; 50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Power consumption<\/td>\n<td width=\"610\">&lt;60W (working state)<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Operating temperature<\/td>\n<td width=\"610\">0\u2103~+50\u2103<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Storage temperature<\/td>\n<td width=\"610\">-40\u2103\uff5e+70\u2103<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Electromagnetic compatibility<\/td>\n<td width=\"610\">Conforms to GJB3947A-2009 3.9.1 Requirements<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Test port<\/td>\n<td width=\"610\">4041D\/E: Type-N (f)<\/p>\n<p>4041F\/G: 2.4 mm (m)<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Auxiliary test interface<\/td>\n<td width=\"610\">10 MHz reference input\/output: BNC female \u00a0 connector<\/p>\n<p>External trigger input: BNC female connector<\/p>\n<p>Intermediate frequency output: BNC female \u00a0 connector<\/p>\n<p>GPS antenna input: BNC female connector<\/td>\n<\/tr>\n<tr>\n<td width=\"308\">Other interfaces<\/td>\n<td width=\"610\">LAN, USB, VGA output<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The 4041 spectrum analyzer is adopted with the compact portable box structure, which has advantages of small size, light weight, low power consumption and convenient carrying. The broadband millimeter-wave receiver miniaturization integrated design technology, whole phase locking technology based on the broadband VCO, full digital intermediate frequency design technology, and microwave composite multilayer circuit board design technology are adopted for this product, thus realizing high performance indicators and ensuring the economical efficiency of the product.<\/p>\n<p>The 4041 spectrum analyzer series currently consists of four types of products. The frequency measurement range covers 9kHz~20GHz, 9kHz~26.5GHz, 9kHz~32GHz and 9kHz~44GHz respectively. The full spectrum of the product is equipped with a preamplifier, so that it has very high receiving sensitivity at any frequency point. In addition, with the 12.1-inch high brightness LCD and integrated design of capacitive touch screen, large button and virtual button combination design, its operation convenience is improved. For its performance indicators, it has excellent average noise level and phase noise indicator as well as the high scanning speed. For its measurement function, it has the option modes including the interference analyzer channel scanner, AM\/FM\/PM analyzer, and power meter, as well as a variety of measurement functions including the channel power, occupied bandwidth, adjacent channel power, audio demodulation, emission mask and carrier-to-noise ratio. This product can be used for the test and maintenance of the aviation, spaceflight, wireless communications and radar signals and devices, and it can also be used for the research, development and production of electronic products and the teaching experiment of scientific research institutes.<\/p>\n<h5><a href=\"http:\/\/en.ceyear.com\/product\/detail-9008.html#\">4041 Series Spectrum Analyzer Purchase Guide.pdf<\/a><\/h5>\n<h5><a href=\"http:\/\/en.ceyear.com\/product\/detail-9008.html#\">4041 Series Spectrum Analyzer Quick Start Guide.pdf<\/a><\/h5>\n<h5><a href=\"http:\/\/en.ceyear.com\/product\/detail-9008.html#\">4041 Series Spectrum Analyzer User Manual.pdf<\/a><\/h5>\n<h5><a href=\"http:\/\/en.ceyear.com\/product\/detail-9008.html#\">4041 Series Spectrum Analyzer Maintenance Manual.pdf<\/a><\/h5>\n<h5><a href=\"http:\/\/en.ceyear.com\/product\/detail-9008.html#\">4041 Series Spectrum Analyzer Maintenance Manual .pdf<\/a><\/h5>\n<h5><a href=\"http:\/\/en.ceyear.com\/product\/detail-9008.html#\">4041 Series Spectrum Analyzer Programming Manual.pdf<\/a><\/h5>\n","protected":false},"featured_media":32747,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[1983,40,41,558],"product_tag":[2040,2039,2038,2036,259],"class_list":{"0":"post-32746","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ceyear","7":"product_cat-rf-microwave","8":"product_cat-spectrum-analysers","9":"product_cat-spectrum-analyzers","10":"product_tag-4041d-e-f-g-spectrum-analyzer","11":"product_tag-ceyear-4041-spectrum-analyzer","12":"product_tag-ceyear-4041d-e-f-g-spectrum-analyzer","13":"product_tag-ceyear-spectrum-analyzer","14":"product_tag-spectrum-analyzer","16":"first","17":"instock","18":"shipping-taxable","19":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product\/32746","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/comments?post=32746"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/media\/32747"}],"wp:attachment":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/media?parent=32746"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_brand?post=32746"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_cat?post=32746"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_tag?post=32746"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}