{"id":32022,"date":"2022-07-27T13:38:59","date_gmt":"2022-07-27T13:38:59","guid":{"rendered":"https:\/\/coral-i.co.za\/test-equipment\/?post_type=product&#038;p=32022"},"modified":"2022-07-27T13:39:00","modified_gmt":"2022-07-27T13:39:00","slug":"modulated-wideband-power-amplifier-tbmda3","status":"publish","type":"product","link":"https:\/\/coral-i.co.za\/test-equipment\/product\/modulated-wideband-power-amplifier-tbmda3\/","title":{"rendered":"Modulated Wideband Power Amplifier TBMDA3"},"content":{"rendered":"<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/TBMDA3_Manual.pdf\" target=\"_blank\" rel=\"noopener\">TBMDA3 manual<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/AN_Immunity_testing-_Tekbox_TEM_Cell.pdf\" target=\"_blank\" rel=\"noopener\">Application Note: Immunity testing example using Tekbox TEM Cells<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/AN_spectrum_analyzers_for_EMC_testing.pdf\" target=\"_blank\" rel=\"noopener\">Application note: How to correctly use spectrum analyzers for EMC pre-compliance tests<\/a><\/div>\n<div><\/div>\n<div>\n<h4>SPECIFICATIONS<\/h4>\n<div class=\"section__content\">\n<p><strong>Input \/ Output:<\/strong>\u00a050 Ohm, N female<br \/>\n<strong>Supply Voltage range:<\/strong>\u00a0110 V\u2026240 V<br \/>\n<strong>Supply power consumption:<\/strong>\u00a020 W<br \/>\n<strong>Maximum input power:<\/strong>\u00a0+3 dBm<br \/>\n<strong>Operating temperature range:<\/strong>\u00a0-20\u00b0C to 50\u00b0C<br \/>\n<strong>Frequency range:<\/strong>\u00a010 MHz \u2013 1 GHz<br \/>\n<strong>1dB output compression point @ 10MHz:<\/strong>\u00a0+36 dBm typ<br \/>\n<strong>1dB output compression point @ 100 MHz:<\/strong>\u00a0+37 dBm typ<br \/>\n<strong>1dB output compression point @ 500 MHz:<\/strong>\u00a0+36 dBm typ<br \/>\n<strong>1dB output compression point @ 1 GHz:<\/strong>\u00a0+34 dBm typ<br \/>\n<strong>Harmonics:<\/strong>\u00a0&lt; \u2013 10 dBc typ.<br \/>\n<strong>Internal modulation frequency AM:<\/strong>\u00a01 kHz \u00b110%<br \/>\n<strong>Internal modulation frequencies PM:<\/strong>\u00a01 kHz \u00b110%, 217 Hz \u00b120%<br \/>\n<strong>Duty cycle, PM:<\/strong>\u00a050% \u00b110% @ 1 kHz; 12.5% \u00b120% @ 217 Hz<\/p>\n<p>Gain:<\/p>\n<table border=\"1\" width=\"544\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td>3 MHz<\/td>\n<td>7 MHz<\/td>\n<td>10 MHz<\/td>\n<td>25 MHz<\/td>\n<td>100 MHz<\/td>\n<td>200 MHz<\/td>\n<td>300 MHz<\/td>\n<td>400 MHz<\/td>\n<td>500 MHz<\/td>\n<\/tr>\n<tr>\n<td>22.5 dB<\/td>\n<td>39.6 dB<\/td>\n<td>42.7 dB<\/td>\n<td>44.7 dB<\/td>\n<td>44.7 dB<\/td>\n<td>44.4 dB<\/td>\n<td>43.7 dB<\/td>\n<td>42.6 dB<\/td>\n<td>42.3 dB<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table border=\"1\" width=\"473\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td>600 MHz<\/td>\n<td>700 MHz<\/td>\n<td>800 MHz<\/td>\n<td>900 MHz<\/td>\n<td>1 GHz<\/td>\n<td>1.1 GHz<\/td>\n<td>1.2 GHz<\/td>\n<\/tr>\n<tr>\n<td>41.8 dB<\/td>\n<td>41.9 dB<\/td>\n<td>40.6 dB<\/td>\n<td>41.5 dB<\/td>\n<td>39.9 dB<\/td>\n<td>37.5 dB<\/td>\n<td>29.8 dB<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The TBMDA3 modulated wideband power amplifier is designed in order to create an inexpensive signal source for immunity testing of electronic building blocks and products. It is designed to be driven by the tracking generator output of spectrum analyzers. With its high gain, it can boost the output power of any tracking generator up to 5W. The TBMDA3 is ideal to drive Tekbox near field probes in order to find the sensitive spot of an electronic circuit or to create electric fields up to 550V\/m when driving the Tekbox TEM Cell TBTC0, 300V\/m when driving the TBTC1, 150V\/m when driving the TBTC2 or 100V\/m when driving the TBTC3. Test signals for immunity testing can be CW, AM or PM modulated. Consequently, the TBMDA3 provides built in modulation capability to generate 1 kHz AM or PM signals. In PM mode, the TBMDA3 can also generate a 217 Hz Signal with 12.5% duty cycle in order to simulate mobile phone TDMA noise.<\/p>\n","protected":false},"featured_media":32023,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[40,1510],"product_tag":[1582,1583],"class_list":{"0":"post-32022","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-rf-microwave","7":"product_cat-tekbox","8":"product_tag-modulated-wideband-power-amplifier-tbmda3","9":"product_tag-tekbox-modulated-wideband-power-amplifier-tbmda3","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product\/32022","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/comments?post=32022"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/media\/32023"}],"wp:attachment":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/media?parent=32022"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_brand?post=32022"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_cat?post=32022"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_tag?post=32022"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}