{"id":31933,"date":"2022-07-27T12:25:45","date_gmt":"2022-07-27T12:25:45","guid":{"rendered":"https:\/\/coral-i.co.za\/test-equipment\/?post_type=product&#038;p=31933"},"modified":"2022-07-27T12:26:59","modified_gmt":"2022-07-27T12:26:59","slug":"tbl5016-3-50-ohm-50-%c2%b5h-5-ohm-16a-lisn-4-paths-cispr-16-1-2","status":"publish","type":"product","link":"https:\/\/coral-i.co.za\/test-equipment\/product\/tbl5016-3-50-ohm-50-%c2%b5h-5-ohm-16a-lisn-4-paths-cispr-16-1-2\/","title":{"rendered":"TBL5016-3 50 Ohm \/\/ 50 \u00b5H + 5 Ohm, 16A LISN, 4 paths, CISPR 16-1-2"},"content":{"rendered":"<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/TBL5016-3_LISN-Manual.pdf\" target=\"_blank\" rel=\"noopener\">TBL5016-3 Manual<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/LISN_Basics_and_Overview.pdf\" target=\"_blank\" rel=\"noopener\">LISN basics and overview<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/EMC_pre_compliance_testing.pdf\" target=\"_blank\" rel=\"noopener\">EMC pre compliance testing guide<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/Pre-Compliance_Conducted_Emission_Measurements.pdf\" target=\"_blank\" rel=\"noopener\">EMC pre compliance conducted emission measurements<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/Which_standard_has_to_be_applied_for_my_product.pdf\" target=\"_blank\" rel=\"noopener\">Which standard has to be applied for my product?<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/AN_spectrum_analyzers_for_EMC_testing.pdf\" target=\"_blank\" rel=\"noopener\">Application note: How to correctly use spectrum analyzers for EMC pre-compliance tests<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/emcview-pc-software-emc-compliance-testing\/\" target=\"_blank\" rel=\"noopener\">EMCview PC software for EMC pre-compliance testing<\/a><\/div>\n<p>The TBL5016-3 is a Line Impedance Stabilization Network for the measurement of line-conducted interference within the range of 9 kHz to 30MHz, according to the CISPR 16-1-2 standard. The device is designed for testing 3-phase and single-phase, AC-powered equipment with supply voltages up to a maximum 450V\/260V and 16A. Conducted noise can be measured on each phase and on the neutral conductor. The TBL5016-3 has separate RF outputs for each phase and neutral and consequently can be coupled with the TBLM1 to split the emissions in its common mode and differential mode components.<br \/>\nThe single-phase DUT socket is available in country-specific variants.<\/p>\n","protected":false},"excerpt":{"rendered":"<ul>\n<li>Frequency range: 9 kHz to 30 MHz<\/li>\n<li>Impedance: 50 \u2126 \u2551 (50 \u00b5H + 5 \u2126)<\/li>\n<li>Artificial hand: 220 pF + 511 \u2126<\/li>\n<li>Switchable PE: 50 \u2126 \u2551 50 \u00b5H<\/li>\n<li>250\u00b5H pre-filter<\/li>\n<li>Separate RF outputs for each line and neutral<\/li>\n<li>Air core inductors<\/li>\n<li>Line voltage: max. 540V\/260V \/ 50 \u2013 60 Hz, CAT \u2016<\/li>\n<li>Max. current per line and neutral: 16A @ 23\u00b0C each<\/li>\n<li>3-phase DUT socket: CEE\/IEC60309, 3L+N+PE, 16A, female<\/li>\n<li>Single-phase DUT socket: country specific<\/li>\n<li>Power connector: CEE\/IEC60309, 3L+N+PE, 16A, male<\/li>\n<li>Measurement connectors: 50 \u2126 BNC<\/li>\n<li>Operating Temperature Range: +5\u00b0C \u2026 + 40\u00b0C; 5% to 80% RH<\/li>\n<li>Safety: Safety Class I, IEC 1010-01<\/li>\n<\/ul>\n","protected":false},"featured_media":31941,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[40,1510],"product_tag":[1545,1550,1551],"class_list":{"0":"post-31933","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-rf-microwave","7":"product_cat-tekbox","8":"product_tag-tbl0550-1-5-h-50a-lisn-cispr-16-1-2-cispr-25-1-path-en-55025-mil-std-461f","9":"product_tag-tbl5016-3-50-ohm-50-h-5-ohm-16a-lisn-4-paths-cispr-16-1-2","10":"product_tag-tekbox-tbl5016-3-50-ohm-50-h-5-ohm-16a-lisn-4-paths-cispr-16-1-2","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product\/31933","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/comments?post=31933"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/media\/31941"}],"wp:attachment":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/media?parent=31933"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_brand?post=31933"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_cat?post=31933"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_tag?post=31933"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}