{"id":31929,"date":"2022-07-27T12:22:11","date_gmt":"2022-07-27T12:22:11","guid":{"rendered":"https:\/\/coral-i.co.za\/test-equipment\/?post_type=product&#038;p=31929"},"modified":"2022-07-27T12:22:12","modified_gmt":"2022-07-27T12:22:12","slug":"tbl5016-2-50-ohm-50-%c2%b5h-5-ohm-16a-lisn-2-paths-cispr-16-1-2","status":"publish","type":"product","link":"https:\/\/coral-i.co.za\/test-equipment\/product\/tbl5016-2-50-ohm-50-%c2%b5h-5-ohm-16a-lisn-2-paths-cispr-16-1-2\/","title":{"rendered":"TBL5016-2 50 Ohm \/\/ 50 \u00b5H + 5 Ohm, 16A LISN, 2 paths, CISPR 16-1-2"},"content":{"rendered":"<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/TBL5016-2_LISN-Manual.pdf\" target=\"_blank\" rel=\"noopener\">TBL5016-2 Manual<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/LISN_Basics_and_Overview.pdf\" target=\"_blank\" rel=\"noopener\">LISN basics and overview<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/EMC_pre_compliance_testing.pdf\" target=\"_blank\" rel=\"noopener\">EMC pre compliance testing guide<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/Pre-Compliance_Conducted_Emission_Measurements.pdf\" target=\"_blank\" rel=\"noopener\">EMC pre compliance conducted emission measurements<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/Which_standard_has_to_be_applied_for_my_product.pdf\" target=\"_blank\" rel=\"noopener\">Which standard has to be applied for my product?<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/AN_spectrum_analyzers_for_EMC_testing.pdf\" target=\"_blank\" rel=\"noopener\">Application note: How to correctly use spectrum analyzers for EMC pre-compliance tests<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/emcview-pc-software-emc-compliance-testing\/\" target=\"_blank\" rel=\"noopener\">EMCview PC software for EMC pre-compliance testing<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/Tekbox_TBL5016_2_ATT_ON.zip\" target=\"_blank\" rel=\"noopener\">TBL5016-2 frequency response file, Attenuator\/Limiter on for EMCview<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/Tekbox_TBL5016_2_ATT_OFF.zip\" target=\"_blank\" rel=\"noopener\">TBL5016-2 frequency response file, Attenuator\/Limiter off for EMCview<\/a><\/div>\n<p>The TBL5016-2 is a Line Impedance Stabilization Network for the measurement of line-conducted interference within the range of 9kHz to 30MHz, according to the CISPR 16-1-2 standard.<\/p>\n<p>The device is designed for testing single phase, AC-powered equipment with supply voltages up to maximum 240V and 16A.<\/p>\n<p>Conducted noise can be measured on the phase and on the neutral conductor. The TBL5016-2 is equipped with a switchable limiter\/attenuator and an artificial hand connection.<\/p>\n<p>The device is available with country-specific DUT connectors.<\/p>\n","protected":false},"excerpt":{"rendered":"<ul>\n<li>Frequency range: 9 kHz to 30 MHz<\/li>\n<li>Impedance: 50 \u03a9 \u2551 (50 \u00b5H + 5 \u03a9)<\/li>\n<li>Artificial hand: 220 pF + 511 \u03a9<\/li>\n<li>Switchable PE: 50 \u03a9 \u2551 50 \u00b5H<\/li>\n<li>Limiter \/ attenuator: 150 kHz to 30 MHz; 10 dB<\/li>\n<li>Air core inductors<\/li>\n<li>Line voltage: max. 240V \/ 50 \u2013 60 Hz, CAT \u2016\u2016<\/li>\n<li>Max. current: 16A @ 23\u00b0C<\/li>\n<li>DUT socket: country specific<\/li>\n<li>Measurement connector: 50 \u03a9 BNC<\/li>\n<li>Power connector: IEC 60320 C19<\/li>\n<li>Operating Temperature Range:\u00a0+5\u00b0C \u2026 + 40\u00b0C; 5% to 80% RH<\/li>\n<li>Safety: Safety Class I, IEC 1010-01<\/li>\n<\/ul>\n","protected":false},"featured_media":31930,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[40,1510],"product_tag":[1547,1549],"class_list":{"0":"post-31929","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-rf-microwave","7":"product_cat-tekbox","8":"product_tag-tblc08-50-ohm-50-h-5-ohm-8a-lisn-2-paths-cispr-16-1-2","9":"product_tag-tekbox-tbl5016-2-50-ohm-50-h-5-ohm-16a-lisn-2-paths-cispr-16-1-2","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product\/31929","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/comments?post=31929"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/media\/31930"}],"wp:attachment":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/media?parent=31929"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_brand?post=31929"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_cat?post=31929"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_tag?post=31929"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}