{"id":31924,"date":"2022-07-27T12:19:21","date_gmt":"2022-07-27T12:19:21","guid":{"rendered":"https:\/\/coral-i.co.za\/test-equipment\/?post_type=product&#038;p=31924"},"modified":"2022-07-27T12:19:21","modified_gmt":"2022-07-27T12:19:21","slug":"tbl5016-1-50-ohm-50-%c2%b5h-5-ohm-16a-lisn-1-path-cispr-16-1-2-mil-std-461f","status":"publish","type":"product","link":"https:\/\/coral-i.co.za\/test-equipment\/product\/tbl5016-1-50-ohm-50-%c2%b5h-5-ohm-16a-lisn-1-path-cispr-16-1-2-mil-std-461f\/","title":{"rendered":"TBL5016-1 50 Ohm \/\/ 50 \u00b5H (+5 Ohm), 16A LISN, 1 path, CISPR 16-1-2, MIL-STD-461F"},"content":{"rendered":"<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/TBL5016-1_LISN-Manual.pdf\" target=\"_blank\" rel=\"noopener\">TBL5016-1 Manual<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/LISN_Basics_and_Overview.pdf\" target=\"_blank\" rel=\"noopener\">LISN basics and overview<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/EMC_pre_compliance_testing.pdf\" target=\"_blank\" rel=\"noopener\">EMC pre compliance testing guide<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/Pre-Compliance_Conducted_Emission_Measurements.pdf\" target=\"_blank\" rel=\"noopener\">EMC pre compliance conducted emission measurements<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/Which_standard_has_to_be_applied_for_my_product.pdf\" target=\"_blank\" rel=\"noopener\">Which standard has to be applied for my product?<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/AN_spectrum_analyzers_for_EMC_testing.pdf\" target=\"_blank\" rel=\"noopener\">Application note: How to correctly use spectrum analyzers for EMC pre-compliance tests<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/emcview-pc-software-emc-compliance-testing\/\" target=\"_blank\" rel=\"noopener\">EMCview PC software for EMC pre-compliance testing<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/Tekbox_TBL5016_1.zip\" target=\"_blank\" rel=\"noopener\">TBL5016-1 frequency response file for EMCView<\/a><\/div>\n<p>The TBL5016-1 50\u00b5H LISN is a device required to setup conducted noise measurements of DC or AC-powered electronic equipment. It is designed according to CISPR 16-1-2 and MIL-STD-461F standard and characterized in the frequency range of 9kHz to 100 MHz.<\/p>\n<p>Apart from carrying out conducted noise measurements, LISNs are also used to establish a defined impedance for various other standardized tests.<\/p>\n<p>The LISN is a 50\u03a9\/50\u00b5H+5 \u03a9 single line design with a high current jumper to short the 5 Ohm resistor and configure it as 50\u03a9\/50\u00b5H LISN according to CISPR 16-1-2. The LISN is characterized up to 100 MHz which means that the LISN can be used for the combined range of 9 kHz to 100 MHz.<\/p>\n<p>The LISN is inserted into the supply line of the DUT (Device Under Test). Conducted noise, which is present at the supply terminals of the DUT can be measured at the BNC connector using a spectrum analyzer or a measurement receiver. The source (supply) terminal and the DUT terminal are decoupled by a 50\u00b5H inductor. DC or single phase measurements typically require a pair of TBL5016-1. Combining it with the Tekbox LISN Mate enables separate measurement of common mode and differential mode noise. DUTs with 3 phase supply require three or four pieces of TBL5016-1, depending on whether the product is supplied in delta or star configuration.<\/p>\n<p>The unit comes equipped with a BNC-male to N-male RG232 cable, mating connectors, high current configuration jumpers and ground brackets to attach it to a ground plane.<\/p>\n","protected":false},"excerpt":{"rendered":"<ul>\n<li>LISN type: V-AMN, configurable as 50\u03a9\/50\u00b5H+5 \u03a9 or 50\u03a9\/50\u00b5H<\/li>\n<li>Frequency range: 9 kHz \u2013 100 MHz<\/li>\n<li>DC Resistance: &lt; 45 m\u03a9<\/li>\n<li>Maximum current: 16A continuous<\/li>\n<li>Operating voltage range: 0 \u2013 250V DC; 0 \u2013 250V AC (50\/60 Hz), 0 \u2013 120V AC (400 Hz)<\/li>\n<li>Fuse: 2 x 16A slow<\/li>\n<li>High current plug\/screw terminals \u2013 male: Phoenix Contact 1998933, female: Phoenix Contact 1967375<\/li>\n<li>Dimensions: 250 mm x 225 mm x 140 mm (including ground brackets)<\/li>\n<li>weight: 2.7 kg<\/li>\n<\/ul>\n","protected":false},"featured_media":31928,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[40,1510],"product_tag":[1545,1548],"class_list":{"0":"post-31924","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-rf-microwave","7":"product_cat-tekbox","8":"product_tag-tbl0550-1-5-h-50a-lisn-cispr-16-1-2-cispr-25-1-path-en-55025-mil-std-461f","9":"product_tag-tbl5016-1-50-ohm-50-h-5-ohm-16a-lisn-1-path-cispr-16-1-2-mil-std-461f","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product\/31924","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/comments?post=31924"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/media\/31928"}],"wp:attachment":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/media?parent=31924"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_brand?post=31924"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_cat?post=31924"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_tag?post=31924"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}