{"id":31888,"date":"2022-07-27T11:38:22","date_gmt":"2022-07-27T11:38:22","guid":{"rendered":"https:\/\/coral-i.co.za\/test-equipment\/?post_type=product&#038;p=31888"},"modified":"2022-07-27T11:38:22","modified_gmt":"2022-07-27T11:38:22","slug":"snap-on-32-mm-up-to-750-mhz","status":"publish","type":"product","link":"https:\/\/coral-i.co.za\/test-equipment\/product\/snap-on-32-mm-up-to-750-mhz\/","title":{"rendered":"Snap On 32 mm up to 750 MHz"},"content":{"rendered":"<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/TBCP2_250_Manual.pdf\" target=\"_blank\" rel=\"noopener\">TBCP2-250 user manual<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/TBCP2_500_Manual.pdf\" target=\"_blank\" rel=\"noopener\">TBCP2-500 user manual<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/TBCP2_750_Manual.pdf\" target=\"_blank\" rel=\"noopener\">TBCP2-750 user manual<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/TBCP2_30K400_Manual.pdf\" target=\"_blank\" rel=\"noopener\">TBCP2-30K400 user manual<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/TBCPx_Calibrators_Manual.pdf\" target=\"_blank\" rel=\"noopener\">TBCP calibration fixture user manual<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/FAQ_Current_Probes.pdf\" target=\"_blank\" rel=\"noopener\">FAQ current probes<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/AN_-RF_current_probes_in_EMCview.pdf\" target=\"_blank\" rel=\"noopener\">Application note: RF current probes with EMCview<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/AN_-RF_current_to_electric_field_strength_extrapolation.pdf\" target=\"_blank\" rel=\"noopener\">Application note: conversion of common mode currents to radiated emissions on cables<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/AN_spectrum_analyzers_for_EMC_testing.pdf\" target=\"_blank\" rel=\"noopener\">Application note: How to correctly use spectrum analyzers for EMC pre-compliance tests<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/AN_-RF_current_to_electric_field_strength_extrapolation_files.rar\" target=\"_blank\" rel=\"noopener\">Conversion files for the AN conversion of common mode currents to radiated emissions on cables<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/Tekbox_Current_Probe_TBCP2_250.zip\" target=\"_blank\" rel=\"noopener\">TBCP2-250 correction file for EMCView<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/Tekbox_Current_Probe_TBCP2_500.zip\" target=\"_blank\" rel=\"noopener\">TBCP2-500 correction file for EMCView<\/a><\/div>\n<div class=\"documentation__item\"><a class=\"link\" href=\"https:\/\/www.tekbox.com\/product\/Tekbox_Current_Probe_TBCP2_750.zip\" target=\"_blank\" rel=\"noopener\">TBCP2-750 correction file for EMCView<\/a><\/div>\n<div><\/div>\n<div>\n<p>TBCP2-250<\/p>\n<ul>\n<li>Characterized frequency range: 30 kHz to 250 MHz<\/li>\n<li>Aperture diameter: 32 mm<\/li>\n<li>Outside diameter: 73 mm<\/li>\n<li>Height: 20 mm<\/li>\n<li>Weight: 320 g<\/li>\n<li>Connector type: N female<\/li>\n<li>Transfer impedance: 0 to 14 dB\u2126 between 100 kHz and 250 MHz<\/li>\n<li>Max. primary current (DC \u2013 400 Hz): 80 A<\/li>\n<li>Max. primary current (RF): 3 A<\/li>\n<li>Max. core temperature: 125 \u00b0C<\/li>\n<\/ul>\n<p>TBCP2-500<\/p>\n<ul>\n<li>Characterized frequency range: 30 kHz to 600 MHz<\/li>\n<li>Aperture diameter: 32 mm<\/li>\n<li>Outside diameter: 73 mm<\/li>\n<li>Height: 20 mm<\/li>\n<li>Weight: 320 g<\/li>\n<li>Connector type: N female<\/li>\n<li>Transfer impedance: 0 to 18 dB\u2126 between 100 kHz and 500 MHz<\/li>\n<li>Max. primary current (DC \u2013 400 Hz): 80 A<\/li>\n<li>Max. primary current (RF): 3 A<\/li>\n<li>Max. core temperature: 125 \u00b0C<\/li>\n<\/ul>\n<p>TBCP2-750<\/p>\n<ul>\n<li>Characterized frequency range: 30 kHz to 800 MHz<\/li>\n<li>Aperture diameter: 32 mm<\/li>\n<li>Outside diameter: 73 mm<\/li>\n<li>Height: 20 mm<\/li>\n<li>Weight: 320 g<\/li>\n<li>Connector type: N female<\/li>\n<li>Transfer impedance: 0 to 20 dB\u2126 between 150 kHz and 750 MHz<\/li>\n<li>Max. primary current (DC \u2013 400 Hz): 80 A<\/li>\n<li>Max. primary current (RF): 3 A<\/li>\n<li>Max. core temperature: 125 \u00b0C<\/li>\n<\/ul>\n<p>TBCP2-30K400<\/p>\n<ul>\n<li>Characterized frequency range: 10 Hz to 500 MHz<\/li>\n<li>Aperture diameter: 32 mm<\/li>\n<li>Outside diameter: 73 mm<\/li>\n<li>Height: 20 mm<\/li>\n<li>Weight: 320 g<\/li>\n<li>Connector type: N female<\/li>\n<li>Transfer impedance: 2 dB Ohm with a 3 dB bandwidth from 30 kHz to 400 MHz<\/li>\n<li>Max. primary current (DC \u2013 400 Hz): 25 A<\/li>\n<li>Max. primary current (RF): 2 A<\/li>\n<li>Max. core temperature: 125 \u00b0C<\/li>\n<\/ul>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The TBCP2-250 is a snap-on RF current monitoring probe. The probe has a very flat response with a 3dB bandwidth of 250 MHz and is characterized over the frequency range from 30kHz to 300 MHz. Upon request, it can also be supplied with a test protocol covering the frequency range 1 kHz to 350 MHz. The aperture of the RF current monitoring probe is 32 mm. Its transfer impedance is &gt; 12 dB Ohm in the range from 700 kHz to 300 MHz.<\/p>\n<p>The TBCP2-500 is a snap-on RF current monitoring probe. The probe has a flat response with a 3dB bandwidth of 500 MHz and is characterized over the frequency range from 30kHz to 600 MHz. Upon request, the test protocol can be extended to frequencies down to 1 kHz. The aperture of the RF current monitoring probe is 32 mm. Its transfer impedance is &gt; 15 dB Ohm in the range from 1 MHz to 500 MHz.<\/p>\n<p>The TBCP2-750 is a snap-on RF current monitoring probe. The probe has a very flat response with a 3dB bandwidth of 750 MHz and is characterized over the frequency range from 30kHz to 800 MHz. Upon request, the test protocol can be extended to frequencies down to 1 kHz. The aperture of the RF current monitoring probe is 32 mm. Its transfer impedance is &gt; 15 dB Ohm in the range from 1 MHz to 750 MHz.<\/p>\n<p>The TBCP2-30K400 is a snap-on RF current monitoring probe. The probe has a very flat response from 30kHz to 500 MHz and is characterized over the frequency range from 10 Hz to 500 MHz. The TBCP5-30K400 is for RF current monitoring applications that need higher sensitivity in the low frequency range, compared to our other current monitoring probe series. The higher sensitivity at low frequencies comes at the cost of a slightly reduced overall trans-impedance.<\/p>\n<p>Tekbox supplies a calibration fixture corresponding with the TBCP2 series of snap on current probes.<\/p>\n","protected":false},"featured_media":31889,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[40,1510],"product_tag":[1531,1532],"class_list":{"0":"post-31888","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-rf-microwave","7":"product_cat-tekbox","8":"product_tag-snap-on-32-mm-up-to-750-mhz","9":"product_tag-tekbox-snap-on-32-mm-up-to-750-mhz","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product\/31888","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/comments?post=31888"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/media\/31889"}],"wp:attachment":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/media?parent=31888"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_brand?post=31888"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_cat?post=31888"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_tag?post=31888"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}