{"id":31182,"date":"2020-11-05T07:53:13","date_gmt":"2020-11-05T07:53:13","guid":{"rendered":"https:\/\/coral-i.co.za\/test-equipment\/?post_type=product&#038;p=31182"},"modified":"2022-02-16T09:28:56","modified_gmt":"2022-02-16T09:28:56","slug":"chauvin-arnoux-ca1631-current-voltage-calibrator-0-%e2%86%92-24-ma","status":"publish","type":"product","link":"https:\/\/coral-i.co.za\/test-equipment\/product\/chauvin-arnoux-ca1631-current-voltage-calibrator-0-%e2%86%92-24-ma\/","title":{"rendered":"Chauvin Arnoux CA1631 Current &#038; Voltage Calibrator 0 \u2192 24 mA"},"content":{"rendered":"<div id=\"pagecell\">\n<div class=\"advLineLevelContainer container\">\n<div class=\"col-xs-12 content\">\n<div class=\"col-xs-8 content-left\">\n<div class=\"prodDetailsContainer top20\">\n<div class=\"rangeOverview sub-range\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-268\" src=\"https:\/\/chauvin-arnoux.africa\/wp-content\/uploads\/2020\/11\/imagesC36AQUJQ.jpg\" alt=\"\" width=\"225\" height=\"225\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-266\" src=\"https:\/\/chauvin-arnoux.africa\/wp-content\/uploads\/2020\/11\/ca16-500x500-1-300x300.jpg\" alt=\"\" width=\"226\" height=\"226\" \/><\/p>\n<div class=\"wrapper\">\n<div class=\"page\">\n<div class=\"main-container col2-right-layout\">\n<div class=\"main\">\n<aside class=\"col-right sidebar\">\n<div class=\"docs\">\n<ul>\n<li class=\"title\">\n<h3 class=\"h3 label-category\">Sales literature<\/h3>\n<\/li>\n<li class=\"wimg\">\n<div class=\"text\"><a class=\"pdf link_document icon-PDF\" href=\"https:\/\/catalog.chauvin-arnoux.com\/fr_en\/dc-gb-ca1631-environmental-measurements.html\" target=\"_blank\" rel=\"noopener noreferrer\">Environmental measurements<\/a><\/div>\n<\/li>\n<li class=\"wimg\">\n<div class=\"text\"><a class=\"pdf link_document icon-PDF\" href=\"https:\/\/catalog.chauvin-arnoux.com\/fr_en\/dc-gb-ca1631-ca-162116231631.html\" target=\"_blank\" rel=\"noopener noreferrer\">CA 1621\/1623\/1631<\/a><\/div>\n<\/li>\n<\/ul>\n<ul>\n<li class=\"title\">\n<h3 class=\"h3 label-category\">User&#8217;s manual<\/h3>\n<\/li>\n<li class=\"wimg\">\n<div class=\"text\"><a class=\"pdf link_document icon-PDF\" href=\"https:\/\/catalog.chauvin-arnoux.com\/fr_en\/nf-gb-ca1631-ca-1631.html\" target=\"_blank\" rel=\"noopener noreferrer\">CA 1631<\/a><\/div>\n<\/li>\n<\/ul>\n<\/div>\n<\/aside>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p class=\"range-paragraph\">These compact, robust, easy-to-handle calibrators have large LCD screens and are suitable for use in highly diverse on-site conditions. They can calibrate an instrument in its operating environment and without removing it from the process. The principal functions are simulation and measurement. They simulate a signal or generate a quantity with precisely-defined values, for applying upstream of the measurement chain, and measure the signal. The CA1621, CA1623 &amp; CA1631 calibrators are designed to accurately measure, generate or simulate all the low-level signals encountered in industry. Applications include maintenance operations, commissioning, verification, on-line calibration and adjustment and testing of measurement lines.<\/p>\n<p class=\"overViewList range-list\">Instruments for use in developing and verifying measurement chains<br \/>\nCA1621 temperature calibrator for J,K,T,E,R,S,B,N thermocouples and voltage in mV<br \/>\nCA1623 temperature calibrator for Pt10,Pt50,Pt100,Pt200,Pt500,Pt1000 and Pt1000(JIS) probes and resistance<br \/>\nCA1631 current loop calibrator for measuring and supplying DC current loop 0 to 24mA, dc voltage between 0 and 20V<br \/>\nCalibrator dimensions 205 x 97 x 45mm<br \/>\nCalibrator weight 472g<\/p>\n<div id=\"pagecell\">\n<div class=\"advLineLevelContainer container\">\n<div class=\"col-xs-12 content\">\n<div class=\"col-xs-8 content-left\">\n<div class=\"heading divider-red\"><strong>Specification<\/strong><\/div>\n<div class=\"specifications\">\n<table class=\"table table-striped\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"table-title\">\n<th>Attribute<\/th>\n<th>Value<\/th>\n<\/tr>\n<tr>\n<td>Absolute Maximum Voltage Measurement<\/td>\n<td>20V dc<\/td>\n<\/tr>\n<tr>\n<td>Absolute Maximum Current Measurement<\/td>\n<td>24mA<\/td>\n<\/tr>\n<tr>\n<td>Best Accuracy<\/td>\n<td>\u00b10.015 %<\/td>\n<\/tr>\n<tr>\n<td>Power Source<\/td>\n<td>Battery, Mains<\/td>\n<\/tr>\n<tr>\n<td>Battery Type<\/td>\n<td>AAA<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>205 x 98 x 46mm<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>472g<\/td>\n<\/tr>\n<tr>\n<td>Height<\/td>\n<td>45mm<\/td>\n<\/tr>\n<tr>\n<td>Length<\/td>\n<td>205mm<\/td>\n<\/tr>\n<tr>\n<td>Maximum Operating Temperature<\/td>\n<td>55\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Maximum Source Current<\/td>\n<td>24mA<\/td>\n<\/tr>\n<tr>\n<td>Minimum Source Voltage<\/td>\n<td>0V<\/td>\n<\/tr>\n<tr>\n<td>Model Number p<\/td>\n<td>CA1631<\/td>\n<\/tr>\n<tr>\n<td>Minimum Operating Temperature<\/td>\n<td>-10\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Minimum Source Current<\/td>\n<td>0mA<\/td>\n<\/tr>\n<tr>\n<td>Width<\/td>\n<td>97mm<\/td>\n<\/tr>\n<tr>\n<td>Maximum Source Voltage<\/td>\n<td>0 mA, 20 V<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<div class=\"wrapper\">\n<div class=\"page\">\n<div class=\"main-container col2-right-layout\">\n<div class=\"main\">\n<p>Compact and simple to use, the CA 1631 calibrator is equipped with a wide screen for comfortable reading.<\/p>\n<div class=\"product-view\">\n<div class=\"product-essential\">\n<form id=\"product_addtocart_form\" action=\"https:\/\/catalog.chauvin-arnoux.com\/fr_en\/checkout\/cart\/add\/uenc\/aHR0cHM6Ly9jYXRhbG9nLmNoYXV2aW4tYXJub3V4LmNvbS9mcl9lbi9jLWEtMTYzMS5odG1s\/product\/3547\/form_key\/sN4cYNOJw9uEyEYn\/\" method=\"post\">\n<section id=\"produit\" class=\"colunik\">\n<div class=\"fiche\">\n<div class=\"caracts central-zone product-shop\">\n<div id=\"tabs-1\" class=\"descriptif tab\">\n<div class=\"description\">\n<div class=\"std\">\n<div class=\"wrapper\">\n<div class=\"page\">\n<div class=\"main-container col2-right-layout\">\n<div class=\"main\">\n<div class=\"product-view\">\n<div class=\"product-essential\">\n<section id=\"produit\" class=\"colunik\">\n<div class=\"fiche\">\n<div class=\"caracts central-zone product-shop\">\n<div id=\"tabs-1\" class=\"descriptif tab\">\n<div class=\"description\">\n<div class=\"std\">\n<p>The CA 1631 can be used to measure and supply a DC current loop from 0 to 24 mA with 0.015% accuracy and a DC voltage between 0 and 20 V with an accuracy of \/- 0.02 %.<\/p>\n<p>When used as a battery-powered stand-alone instrument, it offers a long battery life in the field. When connected to the mains, it can be used continuously without any time limit.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/form>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"featured_media":31183,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[48,55,1239,350],"product_tag":[1240,1241,1242,1243],"class_list":{"0":"post-31182","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ac-dc","7":"product_cat-chauvin-arnoux","8":"product_cat-current-voltage-calibrator","9":"product_cat-power-monitoring","10":"product_tag-chauvin-arnoux-ca1631","11":"product_tag-chauvin-arnoux-ca1631-current-voltage-calibrator","12":"product_tag-chauvin-arnoux-current-voltage-calibrator","13":"product_tag-current-voltage-calibrator","15":"first","16":"instock","17":"shipping-taxable","18":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product\/31182","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/comments?post=31182"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/media\/31183"}],"wp:attachment":[{"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/media?parent=31182"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_brand?post=31182"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_cat?post=31182"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/coral-i.co.za\/test-equipment\/wp-json\/wp\/v2\/product_tag?post=31182"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}