| Technical Data | MU61A | MU61B | ||
| DC voltage (Range/Accuracy) |
400mV/±(0.8%+3) 4V/40V/400V/±(0.5%+1) 1000V/±(1%+3) |
40mV/±(0.8%+3) 400mV/±(0.8%+3) 4V/40V/400V/±(0.5%+1) 1000V/±(1%+3) |
||
| AC voltage (Range/Accuracy) |
400mV/±(1.2%+5) 4V/40V/400V/±(1%+3) 750V/±(1.2%+5) |
40mV/±(1.2%+5) 400mV/±(1.2%+5) 4V/40V/400V/±(1%+3) 750V/±(1.2%+5) |
||
| DC current (Range/Accuracy) |
400μA/4000μA/±(1%+2) 40mA/400mA/±(1.2%+3) 4A/10A/±(1.5%+3) |
400μA/4000μA/±(1%+2) 40mA/400mA/±(1.2%+3) 4A/10A/±(1.5%+3) |
||
| AC current (Range/Accuracy) |
400μA/4000μA/±(1.2% +5) 40mA/400mA/±(1.5% +5) 4A/10A/±(2% +5) |
400μA/4000μA/±(1.2% +5) 40mA/400mA/±(1.5% +5) 4A/10A/±(2% +5) |
||
| Resistance (Range/Accuracy) |
400Ω/±(1.2% +2) 4kΩ/40kΩ/400kΩ/±(1% +2) 4MΩ/±(1.2% +2) 40MΩ/±(1.5% +2) |
400Ω/±(1.2% +2) 4kΩ/40kΩ/400kΩ/±(1% +2) 4MΩ/±(1.2% +2) 40MΩ/±(1.5% +2) |
||
| Temperature (Range/Accuracy) |
N/A | -40℃~-20℃/-(8% +5) >-20℃~0℃/±(1.2% +4) >0℃~100℃/±(1.2% +3) >100℃~1000℃/±(2.5% +2) |
||
| Frequency | Range | 10Hz~10MHz | ||
| Accuracy | ±(0.1%+4) | |||
| Frequency response | 45~400Hz | |||
| Duty cycle | 0.1%~99.9% | |||
| Special function | ||||
| Auto/Manual range | √ | √ | ||
| Auto power off | √ | √ | ||
| Diode test | √ | √ | ||
| On/Off buzzer | √ | √ | ||
| EF test | √ | |||
| Triode test | √ | |||
| Max./Min. value display | √ | √ | ||
| Simulation bar | √ | |||
| Auto power off | √ | |||
| Data hold | √ | √ | ||
| Low battery warning | √ | √ | ||
| Relatively testing | √ | √ | ||
| RS232 | √ | |||
| Input protection | √ | √ | ||
| Input resistance | 10MΩ | |||
| Max.display | 4000 | |||
| Power supply | 9V (6F22) battery | |||
| Weight (g) | 370 | |||
| Dimensions (W×H×D) | 180 × 87 × 47 mm | |||
| Technical Data | MU61C | MU61D | MU61E | |
| DC voltage | Range | 600mV/6V/60V 600V/1000V |
220mV/2.2V/22V/220V/1000V | |
| Accuracy | ±(0.5%+1) | ±(0.1%+2) | ||
| AC voltage | Range | 60mV/600mV/6V 60V/600V/750V |
220mV/2.2V/22V/220V/750V | |
| Accuracy | ±(1.0%+3) | ±(0.8%+10) | ||
| DC current | Range | 600μA/6000μA/60mA 600mA/6A/10A |
200μA/2200μA/22mA 220mA/2.2A/10A |
|
| Accuracy | ±(1.0%+3) | ±(0.5%+10) | ||
| AC current | Range | 600μA/6000μA/60mA 600mA/6A/10A |
200μA/2200μA/22mA 220mA/2.2A/10A |
|
| Accuracy | ±(1.2%+5) | ±(0.8%+10) | ||
| Resistance | Range | 600Ω/6kΩ/60kΩ 600kΩ/6MΩ/60MΩ |
220Ω/2.2kΩ/22kΩ 220kΩ/2.2MΩ/22Mv/220MΩ |
|
| Accuracy | ±(1.0%+2) | ±(0.5%+10) | ||
| Temperature | Range | -40℃~1000℃ | N/A | N/A |
| Accuracy | ±(1.2%+3) | N/A | N/A | |
| Frequency | Range | 10Hz~10kHz | 10Hz~220MHz | |
| Accuracy | ±(0.1%+4) | ±(0.01%+5) | ||
| Capacitance | Range | 40nF/400nF/4μF 40μF/400μF/4000μF |
220nF/220nF/2.2μF 220μF/2.2mF/220F |
|
| Accuracy | ±(3.0%+5) | ±(3.0%+5) | ||
| Special function | ||||
| Auto power off | √ | √ | √ | |
| Diode test | √ | √ | √ | |
| RMS | √ | √ | ||
| On/Off buzzer | √ | √ | √ | |
| Max./Min. value display | √ | √ | ||
| Simulation bar | √ | √ | √ | |
| Auto power off | √ | √ | ||
| Data hold | √ | √ | √ | |
| Low battery warning | √ | √ | √ | |
| Background light | √ | √ | ||
| Relatively testing | √ | √ | √ | |
| RS232 | √ | √ | √ | |
| Input protection | √ | √ | √ | |
| Input resistance | 10MΩ | |||
| Max.display | 6000 | 22000 | ||
| Power supply | 9V (6F22) battery | |||
| Weight (g) | 370 | |||
| Dimensions (W×H×D) | 180 × 87 × 47 mm | |||
MU61 Seires Protable Digital Multimeter
R977.50 exVat
.Max. Display 22000
.Capacitor, frequency and temprature measuring
.Max.test voltage up to 1000VDC and 750VAC
.Various kinds of function: auto power off, diode test, triode test, On/Off buzzer, data hold
Related products
R15,899.00 exVat
Clearance Sale
R46,800.00 exVat
Clearance Sale
R2,200.00 exVat
R11,688.00 exVat
Clearance Sale
R9,005.00 exVat
Clearance Sale
R4,463.00 exVat
Sale!
Clearance Sale
Rigol DS1052E | 50 MHz Oscilloscope with 2 channel , 1 GSa/s
Clearance Sale
R5,104.00 exVat