| Technical Data | MU61A | MU61B | ||
| DC voltage (Range/Accuracy) |
400mV/±(0.8%+3) 4V/40V/400V/±(0.5%+1) 1000V/±(1%+3) |
40mV/±(0.8%+3) 400mV/±(0.8%+3) 4V/40V/400V/±(0.5%+1) 1000V/±(1%+3) |
||
| AC voltage (Range/Accuracy) |
400mV/±(1.2%+5) 4V/40V/400V/±(1%+3) 750V/±(1.2%+5) |
40mV/±(1.2%+5) 400mV/±(1.2%+5) 4V/40V/400V/±(1%+3) 750V/±(1.2%+5) |
||
| DC current (Range/Accuracy) |
400μA/4000μA/±(1%+2) 40mA/400mA/±(1.2%+3) 4A/10A/±(1.5%+3) |
400μA/4000μA/±(1%+2) 40mA/400mA/±(1.2%+3) 4A/10A/±(1.5%+3) |
||
| AC current (Range/Accuracy) |
400μA/4000μA/±(1.2% +5) 40mA/400mA/±(1.5% +5) 4A/10A/±(2% +5) |
400μA/4000μA/±(1.2% +5) 40mA/400mA/±(1.5% +5) 4A/10A/±(2% +5) |
||
| Resistance (Range/Accuracy) |
400Ω/±(1.2% +2) 4kΩ/40kΩ/400kΩ/±(1% +2) 4MΩ/±(1.2% +2) 40MΩ/±(1.5% +2) |
400Ω/±(1.2% +2) 4kΩ/40kΩ/400kΩ/±(1% +2) 4MΩ/±(1.2% +2) 40MΩ/±(1.5% +2) |
||
| Temperature (Range/Accuracy) |
N/A | -40℃~-20℃/-(8% +5) >-20℃~0℃/±(1.2% +4) >0℃~100℃/±(1.2% +3) >100℃~1000℃/±(2.5% +2) |
||
| Frequency | Range | 10Hz~10MHz | ||
| Accuracy | ±(0.1%+4) | |||
| Frequency response | 45~400Hz | |||
| Duty cycle | 0.1%~99.9% | |||
| Special function | ||||
| Auto/Manual range | √ | √ | ||
| Auto power off | √ | √ | ||
| Diode test | √ | √ | ||
| On/Off buzzer | √ | √ | ||
| EF test | √ | |||
| Triode test | √ | |||
| Max./Min. value display | √ | √ | ||
| Simulation bar | √ | |||
| Auto power off | √ | |||
| Data hold | √ | √ | ||
| Low battery warning | √ | √ | ||
| Relatively testing | √ | √ | ||
| RS232 | √ | |||
| Input protection | √ | √ | ||
| Input resistance | 10MΩ | |||
| Max.display | 4000 | |||
| Power supply | 9V (6F22) battery | |||
| Weight (g) | 370 | |||
| Dimensions (W×H×D) | 180 × 87 × 47 mm | |||
| Technical Data | MU61C | MU61D | MU61E | |
| DC voltage | Range | 600mV/6V/60V 600V/1000V |
220mV/2.2V/22V/220V/1000V | |
| Accuracy | ±(0.5%+1) | ±(0.1%+2) | ||
| AC voltage | Range | 60mV/600mV/6V 60V/600V/750V |
220mV/2.2V/22V/220V/750V | |
| Accuracy | ±(1.0%+3) | ±(0.8%+10) | ||
| DC current | Range | 600μA/6000μA/60mA 600mA/6A/10A |
200μA/2200μA/22mA 220mA/2.2A/10A |
|
| Accuracy | ±(1.0%+3) | ±(0.5%+10) | ||
| AC current | Range | 600μA/6000μA/60mA 600mA/6A/10A |
200μA/2200μA/22mA 220mA/2.2A/10A |
|
| Accuracy | ±(1.2%+5) | ±(0.8%+10) | ||
| Resistance | Range | 600Ω/6kΩ/60kΩ 600kΩ/6MΩ/60MΩ |
220Ω/2.2kΩ/22kΩ 220kΩ/2.2MΩ/22Mv/220MΩ |
|
| Accuracy | ±(1.0%+2) | ±(0.5%+10) | ||
| Temperature | Range | -40℃~1000℃ | N/A | N/A |
| Accuracy | ±(1.2%+3) | N/A | N/A | |
| Frequency | Range | 10Hz~10kHz | 10Hz~220MHz | |
| Accuracy | ±(0.1%+4) | ±(0.01%+5) | ||
| Capacitance | Range | 40nF/400nF/4μF 40μF/400μF/4000μF |
220nF/220nF/2.2μF 220μF/2.2mF/220F |
|
| Accuracy | ±(3.0%+5) | ±(3.0%+5) | ||
| Special function | ||||
| Auto power off | √ | √ | √ | |
| Diode test | √ | √ | √ | |
| RMS | √ | √ | ||
| On/Off buzzer | √ | √ | √ | |
| Max./Min. value display | √ | √ | ||
| Simulation bar | √ | √ | √ | |
| Auto power off | √ | √ | ||
| Data hold | √ | √ | √ | |
| Low battery warning | √ | √ | √ | |
| Background light | √ | √ | ||
| Relatively testing | √ | √ | √ | |
| RS232 | √ | √ | √ | |
| Input protection | √ | √ | √ | |
| Input resistance | 10MΩ | |||
| Max.display | 6000 | 22000 | ||
| Power supply | 9V (6F22) battery | |||
| Weight (g) | 370 | |||
| Dimensions (W×H×D) | 180 × 87 × 47 mm | |||
MU61 Seires Protable Digital Multimeter
R977.50 exVat
.Max. Display 22000
.Capacitor, frequency and temprature measuring
.Max.test voltage up to 1000VDC and 750VAC
.Various kinds of function: auto power off, diode test, triode test, On/Off buzzer, data hold
Related products
Clamp Meter
R484.50 exVat
R6,522.00 exVat
Clearance Sale
R8,243.00 exVat
Adapter
R9,082.00 exVat
R765.00 exVat
R775.00 exVat
R11,688.00 exVat
R8,953.00 exVat